User Manual
sens07vest
Page 20
May 2020
4.3.2
Profiles configurator (Blackout)
The profile of type "Blackout" requires manual confirmation of con-
sciousness after the dive within a specified time.
The drowning algorithm is based on 4 depth zones:
Safe zone
,
Diving zone
,
Warning zone
and
Inflation zone
:
The diving countdown starts at the specified
value when entering into the
Diving Zone
. In-
flation is triggered when the diving count-
down reaches zero. In a later system revi-
sion, the
Warning Zone
will offer additional
features, but at the moment there is no dif-
ference to the Diving Zone.
Pressing the
Suspend Button
under water
will freeze the inflation countdown for the
specified time (Inflation Delay). This feature
is optional and is activated by the slider “
En-
able Suspend Button
”.
Blackout Countdown starts to count down
when returning to
Safe Zone
after being at
least 10 seconds in the Diving Zone.
Upcoming inflation can only be stopped by
pressing the button.
Combat diver can disable the
LED Signal
un-
der water for this specific profile.
The last segment
Profile Info
offers to name
the profile and to add any kind of free de-
scription for better understanding.
Save changes before returning to the main menu.
PS: Depending on your sens07 app licence an “Advanced” button is
shown which offers more detailed profile configuration.
User Manual
sens07vest
May 2020
Page 21
4.3.3
Profile switcher
Clicking on this segment offers the choice of different profile
switching plans which will be applied when holding the sens07in-
flator button for 2 seconds.
Some of them include the manual mode (off) to deactivate auto-
matic inflation. The manual handle will always inflate the
sen07vest.
Note: Manual mode is only needed for special legal requirements.
We strongly recommend to stay always in automatic mode (don’t
even include the OFF feature into the profile switching plan). Power
consumption is not reduced in manual mode.