Page 82 of 126
Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
3
Configure the EtherNet / IP or PROFINET
interface as required and click the “Exit” button when
complete:
Label
Value*
Description
Endian Mode
[Big-Endian]
Select for Big-Endian data format.
Little-Endian
Select for Little-Endian data format.
DHCP
Enable
Select this option to enable the gauge to automatically acquire its
IP Address, Subnet Mask and Gateway from a DHCP server on
the network.
Disable
Select this option to manually configure the gauge IP Address,
Subnet Mask and Gateway in the fields below:
IP Address
192.168.1.110
Enter the IP address assigned to the gauge in dotted decimal
format.
Subnet Mask
255.255.0.0
Enter the subnet mask for the network in dotted decimal format.
Gateway
192.168.1.1
Enter the gateway for the network in dotted decimal format.
* [ ] indicates factory-default value.
Configuration via input parameters:
This interface may be configured by writing to the following input parameters:
Input parameters
DW
Bit
Comment
Unit
Range/Remark
Default
29
DHCP
0=Disabled
1=Enabled
0
30
IP address
x.x.x.x
C0A8016E
(192.168.1.110)
31
32
Subnet mask
x.x.x.x
FFFF0000
(255.255.0.0)
33
34
Gateway
x.x.x.x
C0A80001
(192.168.1.1)
35
49
Endianess
1=Little endian
0=Big endian
0