Page 90 of 126
Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
DW
Bit
Comment
Unit
Range/Remark
Default
13
2=Display hold
3=Speed hold
4=Reset
14
Logic input 3 polarity
0=Active low
1=Active high
0
15
Must be 0
0=Old format logic inputs
0
12
Logic input(new format;DW12.15=1)
0
Logic input 1 function
0=direction (count down)
1=Length hold
2=Display hold
3=Speed hold
4=Reset
5=End of Reel
0
1
2
3
Logic input 1 polarity
0=Active low
1=Active high
0
4
Logic input 2 function
0=direction (count down)
1=Length hold
2=Display hold
3=Speed hold
4=Reset
5=End of Reel
1
5
6
7
Logic input 2 polarity
0=Active low
1=Active high
0
8
Logic input 3 function
0=direction (count down)
1=Length hold
2=Display hold
3=Speed hold
4=Reset
5=End of Reel
4
9
10
11
Logic input 3 polarity
0=Active low
1=Active high
0
12
Direction setting (available
only when no logic input
for direction)
0=Count up
1=Count down
0
13~
14
Not used
15
Must be 1
1=New format logic inputs