![Proton SL mini 1220 Instruction Manual Download Page 66](http://html1.mh-extra.com/html/proton/sl-mini-1220/sl-mini-1220_instruction-manual_1620414066.webp)
Page 66 of 126
Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
R
EQUEST CONTINUOUSLY REPEATING VALUES FOR ONE OR A RANGE OF
‘O
UTPUT
’
PARAMETERS
The repartition rate is the maximum possible and only limited by the data length and baud rate. The
parameters must be consecutive when requesting multiple parameters.
Request Format 1:
#
Parameter number
Carriage return
Line feed
Request Format 2:
#
First parameter number
Space
Number of parameters
Carriage return
Line feed
Reply Format 1:
Parameter value
Carriage return
Line feed
Reply Format 2:
First output parameter value
Carriage return
Line feed
Second output parameter value
Carriage return
Line feed
Third output parameter and so on, until the end of the range.
R
EQUEST VALUE ONCE FOR ONE OR A RANGE OF
‘O
UTPUT
’
PARAMETERS
The request and reply format is identical to the # format given below except that # is replaced by
~
.