Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
Note:
If the default resolution of 1=0.1 m{ft}{yds}{inch}of the
“Length Offset” (DW14) parameter is too
large, then an enhanced resolution “Length Offset” of 1=0.001 m{ft}{yds}
{inch} can be factory-enabled
in the SL / SLR gauge.
E
XAMPLE IMPLEMENTATION USING
B
ANNER
QS18
LASER EMITTERS AND
QS186LE
NPN
SENSORS
DB25 INTERFACE Socket Connection
QS186LE Laser Emitter / QS18 NPN Sensor wiring colour code
Pin
1
2
3
4
Colour
Brown
White
Blue
Black
When no object is present, laser light from the QS186LE laser emitter illuminates the QS18 NPN
sensor and its SIG output is pulled low; hence the SL / SLR gauge “Length hold” function must
be set
to “active low”.
SL / SLR gauge configuration using the optional AiG2 display unit:
Navigate to the
“
Interface
”
menu and then navigate to the following submenus:
Logic input function:
Select “Length hold” for logic inputs 1
and 2.
Select “Reset length” for logic input γ.
Logic input active state:
Sel
ect “Active low” for logic inputs 1, β and γ.
Navigate to the “
Measurement
” menu
and then navigate to the following submenu:
Length offset:
Set a positive
value corresponding to distance “L”.
SL / SLR INTERFACE port
Connector type: DB25 Female Socket
LB1
LB2
QS186LE
Laser
Emitter
QS186LE
Laser
Emitter
QS18
NPN
Sensor
QS18
NPN
Sensor
Reset Length switch