Page 67 of 68
Proton Products InteliSENS DG1130 Diameter Gauge Instruction Manual (Issue 1a)
DW
Bit
Comments
Units
Range/Remark
DW40
Cable position on Z axis
1=1%
0~±100
DW41
Line speed
1=0.1m/min{1=1ft/min}
-32768~32767
DW42
Length
1=0.001m{1=0.001ft}
DW43
DW44
Statistics
0
Normal distribution
0=No;1=Yes
1
Not used
2
SPC is available
0=No;1=Yes
DW45
Statistics remain time
1=1s{1=1m{ft}}
0~65535
DW46
Standard deviation
1=0.01um{mil}
0~20000000
DW47
DW48
Maximum diameter
1=0.01um{mil}
0~20000000
DW49
DW50
Minimum diameter
1=0.01um{mil}
0~20000000
DW51
DW52
Mean diameter
1=0.01um{mil}
0~20000000
DW53
DW54
Chi of normal distribution
1=1%
Not used
DW55
Cp
1=1%
DW56
Cpk
1=1%
DW57
FFT remain time
1=1s
DW58
Control status
0=OFF;1=ON;2=Reset;3=Ready
DW59
Control output
1=0.01%
0~±10000
DW60
DW61
DW62
Communication Bus Type
0=NONE;1=PROFIBUS;2=Ethernet
/IP;3=PROFINET
DW63
Res
DW64
IP address for ETH
xx.xx.xx.xx
DW65
DW66
IP address for iBUS
xx.xx.xx.xx
DW67
DW68
Sub net Mask
xx.xx.xx.xx
DW69
DW70
Gateway
xx.xx.xx.xx
DW71
DW72
Gauge temperature
1=0.1
℃