Page 62 of 68
Proton Products InteliSENS DG1130 Diameter Gauge Instruction Manual (Issue 1a)
DW
Bit
Comments
Unit
Range/Remark
Default value
3
limit;7=Under
Average Lower
limit;8=Over X Upper
limit;9=Under X
Lower limit;10=Over
Y Upper
limit;11=Under Y
Lower limit;12=Over Z
Upper limit;13=Under
Z Lower limit;14=Over
ovality Upper
limit;15=Under Ovality
Lower limit;,
4
Relay 2 function
1
5
6
7
8
Relay 3 function
2
9
10
11
12
Relay 4 function
3
13
14
15
DW51
Relay closure time
1=1ms
1~5000
100
DW52
Source of line speed
0=Preset;1=Pulse;2=
Analouge
0
DW53
Preset line speed
1=1m/min{1=ft/min}
0~65535
1000
DW54
Full scale/gain of line
speed
1=1m/min{1=1ft/min)
or
1=0.0001pulse/meter{
1=0.0001pulse/ft)
1000
DW55
DW56
0~
7
Control switch
0=HOLD;1=ON;2=RE
SET
0
8
Control output polarity
0=Normal;1=Reverse
0
DW57
PID Start Speed
1=1m/min{1=1ft/min}
50
DW58
PID output Range
1=1%
0~50%
50
DW59
Extruder response time
1=1s
0~999s
1
DW60
Distance from gauge head
to extruder
1=0.1m{1=0.1ft}
1~10000
10
DW61
I gain
1=1%
0~100
50
DW62
P gain
1=1%
0~100
50
DW63
Analogue O/P
0
Analogue O/P 1
0=Average ;1=X;2=Y;
3=Z;4=Ovality;5=Aver
age error;6=X
error;7=Y error;8=Z
error;9=Ovaity error;
0
1
2
3
4
Analogue O/P 2
1
5
6
7
8
Analogue O/P 3
2