background image

fixed mount laser scanner

User’s Manual DFM 1000

Summary of Contents for DFM 1000

Page 1: ...fixed mount laser scanner User s Manual DFM 1000 ...

Page 2: ... Opticon has been informed about the possibility of such damages A serial number appears on all Opticon products This official registration number is strictly related to the device purchased Make sure that the serial number appearing on your Opticon device has not been removed Servicing by our Repair Department can only be carried out under warranty All Opticon products are warranted for a period ...

Page 3: ...odes 10 3 2 4 Check mode 11 3 2 5 Formatting the bar code data 11 3 2 6 LED indicator 11 3 2 7 Buzzer signal 11 3 2 8 Serial communication 11 3 2 9 Bar code polarity 11 3 2 10 No Decode signal 11 3 2 11 No Decode message 11 3 2 12 Trigger signal 11 3 2 13 Trigger message 11 3 2 14 Data formatting options 11 4 WORKING WITH THE SCANNER 12 4 1 Scan position 12 4 2 Reading the bar codes 12 USER S MANU...

Page 4: ...ing the terminal to maximise the efficiency of this scanner Do not remove the scanner label On the back housing of every scanner you will find a label The label is attached by the manufacturer and includes information about the power supply to the scanner and a serial number Do not remove it When you remove the packing please check for any physical damage We recommend that you save all packing mat...

Page 5: ...ad LED green default 4 Buzzer Beeper A single tone beep indicates results as defined by the user 5 Connector For RS 232 and RS 485 connection power supply and configurable I O lines 6 Mounting slot Slot for fixed mounting or for DIN rail adapter with adjustable bolts and nuts 7 Scanner label Do not remove it USER S MANUAL DFM1000 5 2 2 1 Dimensions of the scanner 2 2 2 Details of the scanner 2 2 D...

Page 6: ...y attention to the following Use of the DFM1000 For long periods do not use or leave the scanner in area s that are exposed to extreme heat that is higher than 50 oC like direct sunlight or near a heater Also do not expose the scanner to freezing area s Do not subject the scanner to very strong impact do not throw or drop the scanner from large heights Do not plug the DB25 male connector of the sc...

Page 7: ...nd skew angles as described in this chapter Avoid excessive angles 2 4 2 Scanning distance and angles Use the diagram below to see which reading distance should be used related to the bar code resolution Use the other diagram to adjust your scanner to the right angle 5 mm 75 mm 90 mm 130 mm 155 mm 270 mm 360 mm 425 mm 520 mm 750 mm 0 15 6 mil 0 127 5 mil 0 25 10 mil 0 33 13 mil 0 39 15 6 mil 0 5 2...

Page 8: ... Mounting suggestions The DFM1000 can be placed on a flat surface or can be permanently mounted fixed The bottom of the scanner is provided with 2 slots with adjustable bolts and nuts for mounting on e g a DIN rail In every mounting situtation make sure that the bottom of the scanner is positioned under straight angle When you do not fix the scanner do not loosen the bolts To mount the scanner on ...

Page 9: ...de label from the test labels in chapter 9 Scanner beeps Default setting Good Read LED back side scanner flash green shortly Data is sent to the host Default communication settings RS232 9600 N 8 1 Check data at the host 2 5 2 Grounding See grounding diagram Make sure the shielding is grounded only to earth ground at the host The shielding connection to the scanner from the host should not be conn...

Page 10: ...ed off and the user has to retrigger the scanner in order to scan the next label Multiple read mode After a bar code is decoded successfully the laser stays on allowing the user to read another bar code A bar code is only transmit ted once regardless the number of times the scanner reads it Only when the scanner could not decode a bar code for a selected time the laser is shut off Continous read m...

Page 11: ...er can be adjusted by the user 3 2 8 Serial communication For direct communication between the scanner and the host the scanner is provided with RS232 interface Other interfaces are available on request 3 2 9 Bar code polarity The laser scanner is able to red positive and negative labels for both black or coloured labels The following bar code reading options are available Black on white White on ...

Page 12: ...canner should read the bar codes in the reading area If you have problems with the read operation pay attention to the following Check if the scanner is not oblique mounted Check if the scanner is able to decode the bar code referring to the reading angles Check if the position of the bar code label is correct Scan one of the test labels of chapter 9 If the test label is read correctly check the r...

Page 13: ...ORANGE PINK PIN 1 4 RS485 INTERFACE YELLOW GREEN LIGHT GREEN BLUE LIGHT BLUE PIN 6 9 RS232 INTERFACE PURPLE GREY WHITE BLACK BROWN BLACK RED BLACK PIN 14 FOR FUTURE EXPANSION ORANGE BLACK PINK BLACK YELLOW BLACK GREEN BLACK PIN 16 19 FOR FUTURE EXPANSION LIGHT GREEN BLACK BLUE BLACK LIGHT BLUE BLACK PURPLE BLACK GREY BLACK WHITE BLACK FUNCTION TR TR T T not connected RTS CTS RxD TxD SUPPLY VOLTAGE...

Page 14: ...e and or OSEMENU software Interfaces RS232 Upgradeability The software can easily be upgraded using OSEMENU USER S MANUAL DFM1000 14 6 1 Electrical specifications Voltage requirement 9 33V DC unregulated less than 1Vp pripple Power consumption max 4 5 Watt 6 2 Optical specifications Light source 670 nm visible laser diode Deflection system rotating polygon 10 facets Scan rate 1000 scans sec Decode...

Page 15: ... storage Emission According to EN50081 part 1 2 Immunity According to EN50082 part 1 2 Protection against dust and moisture According to IEC529 IP 54 Safety Laser class According to IEC825 Class I laserproduct 6 6 Physical specifications Dimensions l x w x h 143 x 105 x 39 mm Case material aluminium anodised Weight 780g Standard connector DB25 male 1 5m cable ...

Page 16: ... sending the terminal or cradle please use the original packing to minimise the chances of damage Scanner does not function The DB25 male connector of the DFM1000 is not RS232 compatible Check if the scanner is connected as advised in the wiring diagram chapter 2 5 Good Read LED is off Check the power supply If faulty power supply is used replace the power supply Check the cables If faulty cables ...

Page 17: ...k digit for the involved bar code symbology Fixed length is set for the involved bar code symbology Adjust or remove the fixed length check Strange characters are received at host Baudrate databits stop or parity do not match Compare and match these settings between host and scanner Default communication settings 9600 baudrate No parity 8 data bits 1 stop bit No data is received at host and scanne...

Page 18: ...00 laser scanner A15013R0010 including DB25 male connector 1 5 m cable Additional Configuration kit for DFM A83200N0010 including configuration disc with configuration software RS232 adapter RS232 DB9 cable 12V power supply PRODUCT ORDERING INFORMATION 8 ...

Page 19: ...e testing one of the other labels first activate the right bar code symbology in the configuration software of the DFM1000 TEST LABELS 9 UPC A default EAN 13 default ISBN EAN 13 ADDON 5 Code 39 Code 39 FULL ASCII Code 39 Italian Pharmaceutical 0 071589 812308 9 780123 456786 0123456789 7 376221 357463 12345 C O D E 39 Code 39 V2GZD9 908557705 ...

Page 20: ...ndustrial 2 of 5 without CD Interleaved 2 of 5 with CD with bearer bars Telepen ASCII Telepen numeric Code 128 Code C EAN 128 Opticon Article Code O0225000010 0123456789 0123456784 Telepen 57748174857483 0123456789 C10123456789 ...

Reviews: