background image

4

Lamps

Exposure Recomendation

Session Times

•  For optimum results use this product for a minimum period of 10-15 weeks. (Results may           

vary)

•  Sessions should be conducted every other day for no longer than the recommended 15 min-

ute session time.

•  To maintain results, continue using this product 1 time a week for the recommended 15 

minute session. 

Serial Number

Note: We recommend you write down your serial number in the manual to have it on hand 

for any future part orders or service needs.

Model

Lamp

RenuvaSkin JD 3200

Canopy: RenuvaSkin 18 x 75" 110W
Bench: RenuvaSkin 14 x 71" 100W

Summary of Contents for RenuvaSkin JD 3200

Page 1: ...User s Manual 15 Minutes RenuvaSkin JD 3200 by ProSun 15 MINUTES ProSun International LLC 2442 23rd Street North St Petersburg FL 33713 www ProSun com 800 874 2776 E304 031...

Page 2: ...Sun has drawn up a maintenance schedule to ensure good performance and maximum life of your unit It is strongly recommended to adhere to these service instructions and intervals Always disconnect the...

Page 3: ...re Recommended eye wear provided eye shields Intrexco nr 5635 1s or equivalent eyewear as defined under 21CFR1040 20 2 b 6 Two pair of protective eye wear are furnished with this equipment and should...

Page 4: ...longer than the recommended 15 min ute session time To maintain results continue using this product 1 time a week for the recommended 15 minute session Serial Number Note We recommend you write down...

Page 5: ...exposure schedule and proper exposure times for the model that you have purchased The Electrical requirements for your ProSun unit are Model Breaker Volt Hertz Operating Amps 1 RenuvaSkin JD 3200 20 A...

Page 6: ...ment into any room which has not been properly prepared in accordance with these general notes All electrical work shall conform to the requirements of the national electrical code OHSA or applicable...

Page 7: ...7 Head Canopy Feet Bench Unit can only be used by one 1 person during a session Remain laying down during session with face towards facials...

Page 8: ...e must be between 218 230 V Make sure to write the Serial Number located on the back of the canopy down on the previous page and store the manual somewhere you can easily access The Serial Number is M...

Page 9: ...gin 6 Combi Arm Screws FASN1508828 4 Gas Shock Pivots GASP9008435 4 Security Clips GASP90008436 1 Plastic Front Skirt optional bronze CVPL 6012336 red CVPL 6513606 white CVPL 6525156 1 Gas Shock 4 Sec...

Page 10: ...wn Optional Front Skirt if you do not have a plastic front skirt go to step 3 Retrieve 1 Plastic front skirt located in canopy box Remove the screw from the leg Insert plastic front skirt and screw in...

Page 11: ...Flip bench over Retrieve 2 Combi Arms 6 Combi Arm Screws Remove the end cap filler Insert combi arm into bench and secure with screws Repeat these steps on other side 3 4 1 end cap filler bench combi...

Page 12: ...nopy from the box Remove the end cap filler as done previously with the bench While holding the canopy on each end attach it to the bench by sliding it onto the combi arms 5 canopy combi arm end cap f...

Page 13: ...13 Retrieve 2 security plates 4 security plate screws Once the canopy is attached to the bench secure the security plate into place with security plate screws Repeat these steps on other side 6...

Page 14: ...position insert gas shock into the bench and into third hole on the canopy Then insert gas shock pivots and secure with a security clip 7 If the canopy rises spontaneously move gas shock to hole 2 If...

Page 15: ...15 The four end cap fillers that were removed need to be inserted back into the bench and canopy 8 End cap filler End cap filler...

Page 16: ...Shield Retrieve 1 Deco shield 2 deco shield screws 2 deco shield washers 2 deco shield nuts Insert the deco shield in between the canopy and bench 7 Secure by attaching the decor shield to combi arm 8...

Page 17: ...ctions On the back of the canopy you will see three chords Plug A into your wall outlet or into optional buck booster Plug B in the bench C is used for the T Max timer which is an optional additional...

Page 18: ...If the deco shield has an integrated t max system follow the steps below For commercial use only Plug the male end located on the back of deco shield into the female end located on the back of canopy...

Page 19: ...19 If necessary unscrew the backing of the t max timer to expose the 3 data ports Connect the corresponding cables 2 Daisy Chain Connection for wireless adaption...

Page 20: ...tral Pin 3 live 1 2 Optional T Max Connection If you are adding a T Max timer to your unit follow the steps below For commercial use only Remove the male end from the female located on the back of the...

Page 21: ...e Insert one end of the 18 2 cable into the J3 Contact on the back of the T Max Insert the other end into Pins 1 and 3 on the male part Tighten screws to hold cables in place Make sure that the 18 2 c...

Page 22: ...22 After all the appropriate cables connected screw the top back on 4 5 Back of canopy Male Female...

Page 23: ...23 Congratulations Your RenuvaSkin JD 3200 is now ready for use Refer to the operation instructions on the next page to use your new red light unit...

Page 24: ...to run Pressing stop twice will initiate a mandatory after cooling phase of 3 minutes The unit cannot be started during these 3 minutes Remote mode only for commercial units Pressing stop once will c...

Page 25: ...e b Reduce body cooler speed Coin mode a Reduce body cooler speed Stand alone mode a Increase session time b Increase body cooler speed Coin mode a Increase body cooler speed Face Switch the facial li...

Page 26: ...use the unit in stand alone mode follow the steps below Press both stop and and hold for 10 seconds until 01 is shown Press the button and continue to press until the display indicates 15 Press start...

Page 27: ...erheated Communication error No communication between switch print and display print Note When you receive one of the above error messages on your LCD display you should stop using the unit and unplug...

Page 28: ...ecautions when bed is in use Do not disassemble any part of the bed while in use Do not allow sharp objects in the bed while in use Do not allow liquid or any foreign objects to get inside the bed Ens...

Page 29: ...bench Longevity of the acrylic sheets The acrylic sheets used in this machine should be changed between 1200 and 1500 hours of operation If not transmission could be greatly reduced ProSun recommends...

Page 30: ...Click Strips are firmly in place X Clean Sanitize Bed Exterior X Remove Clean inside of acrylic sheets X Dust Lamps X Wipe Vacuum fans vents X Clean all reflectors X Inspect Acrylics for cracks wear X...

Page 31: ...Only use manufacturer authorized replacement components Failure to do so many void warranty High pressure facial lamp 400 Watt replacement Remove the blue and clear filter glasses by loosening their r...

Page 32: ...PROSUN will pay for ground transportation of repaired or replaced part back to purchaser I Tanning units parts or components damaged in transit where PROSUN S damaged goods policy is not followed by p...

Page 33: ...major force or any cause beyond its reasonable control PROSUN S LIABILITY UNDER OR FOR BREACH OF THIS AGREEMENT SHALL NOT EXCEED THE REFUND OF THE PURCHASE PRICE LESS REASONABLE RENTAL FOR PAST USE IN...

Page 34: ...ProSun International LLC 2442 23rd Street North St Petersburg FL 33713 www ProSun com 800 874 2776...

Reviews:

Related manuals for RenuvaSkin JD 3200