WARNING:
Before doing any repair or replacement work on this machine, ALWAYS
disconnect the power at the main circuit breaker(or, if the main power cable has a wall plug,
pull it out).
Lamp replacement:
Holding the lamp at both ends, turn it counter-clockwise until the bi-pins can slide easily out
of the lamp holder socket, and slowly take it out of the unit. Clicks will be heard as the socket
incrementally rotates. Replace the lamp in just the opposite manner, making sure that the
labeling on the lamp itself is pointed outward.
SEE WARNING LABEL FOR LAMP TYPES.
IMPORTANT:
Only use manufacturer-authorized replacement components. Failure to do so
many void warranty.
High pressure facial lamp (400 Watt) replacement:
Remove the blue and clear filter glasses by loosening their respective securing screws on the
frame of the facial light cassette. Making absolutely sure not to touch the glass of the lamp
itself, take it out of its box and set it to the side. Hold the old lamp also by one end and push
it into the opposite end of the spring-loaded lamp holder, until the end you are holding comes
free. Replace the new lamp in just the opposite manner, but do not touch the glass of the
lamp.
SEE WARNING LABEL FOR LAMP TYPES.
IMPORTANT:
Only use manufacturer- authorized replacement components. Failure to do so
may void warranty.
Replacement of Components