MVI56E-AFC / MVI69E-AFC ♦ Enhanced Liquid and Gas Flow Computer
Configuring Common Parameters
ControlLogix® and CompactLogix™
Setup and Configuration Guide
ProSoft Technology, Inc.
Page 67 of 151
Archive Accumulators (2)
Click the
R
ESETTABLE
A
CCUM
button.
The accumulator types are independent. For example, resetting a resettable
accumulator does not affect the other accumulators.
For multiple-stream firmware, each stream also has a set of ten accumulators (six non-
resettable, and four resettable). Increments are applied both to the meter accumulators
and to the accumulators for the active stream.
6.7.1 Non-Resettable Accumulators
The non-resettable accumulators are only reset when the accumulator rollover value is
reached. The accumulator rollover value, and the accumulator unit must be configured
using the EAFC Manager.
The module supports six non-resettable accumulators in order to show the measured
quantity to be totalized.
Non-resettable accumulator mass
Non-resettable accumulator energy (Gas applications)
Non-resettable accumulator net
Non-resettable accumulator gross
Non-resettable accumulator gross standard (Liquid apps only). For Oil-water
emulsion, this is a non-resettable accumulator for gross clean oil.