8681330
10,000W CONSTRUCTION HEATER
V1.0
WITH ENCLOSED MOTOR
8
For technical questions call 1-800-665-8685
WIRING THE HEATER
WARNING! Switch off the appropriate circuit breakers at the
electrical panel before starting to avoid electrical shock.
CAUTION! Use only copper wires that are rated for at least 75 ºC.
1. Slide the copper wires (see table below for wiring
requirements) through the provided cable connectors.
VOLTAGE RATING
CURRENT
RATING
MAX.
FUSE SIZE
MIN. WIRE
SIZE
Single phase
10KW @ 240V
41
60
#6
Three-phase
10KW @ 240V
26
38
#10
IMPORTANT! A conduit may be required for certain
setups. Check with your local electrical codes.
2. Remove the front screws (Fig. 3-2) at the base of the
heater to access the power block.
Fig. 3
Fig. 4