5.3.4 DRAINING WATER FROM AIR TANK
FIGURE 5.7
Draining water from air tank
(1) drain valve, (2) air tank, (3) lower frame
Required maintenance actions
Tilt drain valve stem (1) located in the lower part of tank (2).
The compressed air in the tank causes the removal of water to the
exterior.
Released valve stem should automatically close and stop flow of air from the
tank.
In the event, that the valve stem resists returning to its setting, then
the whole drain valve must be unscrewed and cleaned, or replaced (if
it is damaged) - see section (5.3.5).
Repeat all above steps for the other tank.
Draining water from air tank:
•
after each week of use.