PRONAR T028KM PRONAR T028ML
SECTION 5
5.18
5.3.3 INSPECTION OF THE SYSTEM
During tightness inspection attention should additionally be given to technical condition and
degree of cleanness of the system components. Contact of pneumatic conduit seals etc. with
oil, grease, petrol etc. may cause damage and accelerate the ageing process. Bent,
permanently deformed, cut or worn conduits should be replaced.
INSPECTION
•
Each time during tightness inspection.
5.4 CLEANING THE AIR FILTERS
Depending on trailer working conditions, but not less than once in three months, take out and
clean air filter elements, which are located in pneumatic system connection conduits. Inserts
are used many times and are not subject to changing unless they are mechanically
damaged.
FIGURE 5.9
Air filter
(1) securing slide lock, (2) air filter cover
Required maintenance activities
Reduce pressure in supply conduit.