The warranted operation period of the products is 12 months from the date of 

sale but not longer than 18 months from the day of acceptance by the 

manufacturer’s QCD.  

The warranty does not cover the batteries included in the set. 

Faulty products are accepted for repair only complete, with the compulsory 

preservation of the factory labels on the body of the products.

 

To improve the quality of the product, the manufacturer reserves the right to 
make changes in the design of products without prior notice.

 

12.

 

WARRANTY LIABILITIES

 

The manufacturer, ETC PROMIX LLC, warrants conformity of the products to requirements of 

current technical specifications provided that the transportation, storage, installation and operation 
rules established in this Manual are followed. 

Within the period of warranty, ETC PROMIX LLC undertakes to eliminate defects of the system 

components, caused by the Manufacturer's  fault,  or to replace defective components and units 
free of charge. Costs of delivery to and from the place of repair shall be borne by the Buyer. 

Warranty liabilities do not cover any defects and damages caused by: 

  Improper maintenance by the Buyer; 

  Use of the products under conditions that do not comply with the operation requirements; 

  Mechanical damages or disassembly of the products by the Buyer; 

  Non-observance of the transportation and storage rules. 

After the expiration of the warranty service period, the manufacturer provides post-warranty 

service of the product on a contractual basis. 

13.

 

ACCEPTANCE AND PACKING CERTIFICATE

 

The remote control system 

PROMIX-RDS.01

 in quantity of ___ pieces (1 peace by default) bearing the 

manufacturing date and QCD mark on the body is manufactured and accepted according to 

ПШБА.

464415.1

01  ТУ,  meets  the  obligatory 

requirements of state standards and current technical 

documentation, is recognized fit for operation and packed by ETC PROMIX LLC. 

 
 
 
 
 

Engineering and Technical Center PROMIX LLC 
Russia, 214030, Smolensk, Krasninskoye shosse, 35, letter A

 

Tel. (4812) 619-330 

www.promix-center.com

  

www.facebook.com/Promixcenter

 

[email protected]

 

 

 

Summary of Contents for RDS.01

Page 1: ...eiver and controller unit are designed as a single unit controller Promix CR RX 03 hereinafter the controller The receiver of the controller receives control signals of remote controls Promix CR TX 01 The power supply unit of the controller is used to control the connected actuators 2 DELIVERY SET Controller Promix CR RX 03 1 pc Remote control Promix CR TX 01 with a battery 2 pcs Operating manual ...

Page 2: ...erforms the following functions programming of remote controls and control time of the actuator applying or removing supply voltage to from the actuator for a specified time on the signals of the programmed remote controls disconnecting the actuator from the power supply unit protection when the current consumption by the actuator exceeds the preset level audible signaling of the controller curren...

Page 3: ...ontrol Promix CR TX 01 it sends a unique code via a radio channel The controller Promix CR RX 03 receives the sent code and if this code is recorded in the controller memory see Section 7 activates its output contact for the programmed time the supply voltage is applied to or removed from the actuator what is accompanied by a continuous beep signal If the current in the circuit of the actuator exc...

Page 4: ...open state when there is no supply voltage and in the closed state when the supply voltage is applied A normally closed actuator is in the closed state when there is no supply voltage and in the open state when supply voltage is applied Position 3 programming of the controller 7 PROGRAMMING THE CONTROLLER The supplied remote controls are already recorded in the controller memory The factory settin...

Page 5: ...roller emits double short beeps during which the programming is carried out 7 Pressing the button of the programmed remote control increases the open lock time by 1 second The set time in seconds corresponds to the number of beeps 8 If no action is performed during 5 seconds the controller switches from the programming mode into the operating mode confirming it with three beeps 9 Determine the typ...

Page 6: ...s per GOST R IEC 60065 2009 The insulation strength between the current carrying circuits of the mains supply and the secondary circuits with a low voltage complete device must withstand an AC voltage of 3750V of practically sinusoidal form with a frequency of 50 1 Hz The electrical insulation resistance between the current carrying circuits of the mains supply and the secondary circuits depending...

Page 7: ...omponents and units free of charge Costs of delivery to and from the place of repair shall be borne by the Buyer Warranty liabilities do not cover any defects and damages caused by Improper maintenance by the Buyer Use of the products under conditions that do not comply with the operation requirements Mechanical damages or disassembly of the products by the Buyer Non observance of the transportati...

Reviews: