Since the controller can stay in this mode for an indefinite time, make sure that 

actuator connected to the controller can be supplied with power for a long 

time.

 

4.4 TECHNICAL DATA OF THE REMOTE CONTROL 
PROMIX-CR.TX.01  

Output power, мW, not more than

 

10 

The length of the code, byte

 

4

 

Number of code combinations 

16777216

 

Battery supply voltage (type 23А), V 

12 

Current consumption with pressed button, мА, not more than 

5.

 

DESIGN AND PRINCIPLE OF OPERATION 

 

The controller Promix-CR.RX.03 contains: a connector for connection of the actuator, a mode 

jumper J1, a power cord for connection to  220V power grid  (1.4 m long), an antenna wire. The 
overall dimensions of the controller Promix-CR.RX.03: 111x58x50 mm (LxWxH). 

When pressing the control button on  the remote control  Promix-CR.TX.01, it sends a unique 

code via a radio channel. The controller Promix-CR.RX.03 receives the sent code and, if this code 
is recorded in the controller memory (see Section  7), activates its output contact  for the 
programmed time  (the supply voltage is applied to or removed from the actuator), what is 
accompanied by a continuous beep signal. 

If the current in the circuit of the actuator exceeds the value of the tripping current, the power 

supply will switch off. It can be restored by reconnecting the controller to the power grid. The state 
of the controller after the current protection trips is indicated by short intermittent sound signals. 

When holding down the remote control button for more than 7 seconds, the controller switches 

into the permanently open actuator mode. The controller emits a short trill and then produces 
single beeps. To close the actuator, press the remote control button. The controller will close the 
actuator and emit a beep signal.  

Summary of Contents for RDS.01

Page 1: ...eiver and controller unit are designed as a single unit controller Promix CR RX 03 hereinafter the controller The receiver of the controller receives control signals of remote controls Promix CR TX 01 The power supply unit of the controller is used to control the connected actuators 2 DELIVERY SET Controller Promix CR RX 03 1 pc Remote control Promix CR TX 01 with a battery 2 pcs Operating manual ...

Page 2: ...erforms the following functions programming of remote controls and control time of the actuator applying or removing supply voltage to from the actuator for a specified time on the signals of the programmed remote controls disconnecting the actuator from the power supply unit protection when the current consumption by the actuator exceeds the preset level audible signaling of the controller curren...

Page 3: ...ontrol Promix CR TX 01 it sends a unique code via a radio channel The controller Promix CR RX 03 receives the sent code and if this code is recorded in the controller memory see Section 7 activates its output contact for the programmed time the supply voltage is applied to or removed from the actuator what is accompanied by a continuous beep signal If the current in the circuit of the actuator exc...

Page 4: ...open state when there is no supply voltage and in the closed state when the supply voltage is applied A normally closed actuator is in the closed state when there is no supply voltage and in the open state when supply voltage is applied Position 3 programming of the controller 7 PROGRAMMING THE CONTROLLER The supplied remote controls are already recorded in the controller memory The factory settin...

Page 5: ...roller emits double short beeps during which the programming is carried out 7 Pressing the button of the programmed remote control increases the open lock time by 1 second The set time in seconds corresponds to the number of beeps 8 If no action is performed during 5 seconds the controller switches from the programming mode into the operating mode confirming it with three beeps 9 Determine the typ...

Page 6: ...s per GOST R IEC 60065 2009 The insulation strength between the current carrying circuits of the mains supply and the secondary circuits with a low voltage complete device must withstand an AC voltage of 3750V of practically sinusoidal form with a frequency of 50 1 Hz The electrical insulation resistance between the current carrying circuits of the mains supply and the secondary circuits depending...

Page 7: ...omponents and units free of charge Costs of delivery to and from the place of repair shall be borne by the Buyer Warranty liabilities do not cover any defects and damages caused by Improper maintenance by the Buyer Use of the products under conditions that do not comply with the operation requirements Mechanical damages or disassembly of the products by the Buyer Non observance of the transportati...

Reviews: