TECHNICAL DATA

 

4.1 TECHNICAL DATA OF THE POWER SUPPLY UNIT 

The power supply unit of the controller powers the receiver, controller unit, and actuator. The 

power supply unit is a pulse type, with galvanic isolation of primary and secondary circuits. The 
power supply unit has a built-in overcurrent and short-circuit protection for the load circuit. 

Supply voltage (50 Hz), V 

 

180-230 

Output voltage (direct current), V 

 

12

 

Rated output current, A 

1.0

 

Maximum output current during 1 minute, А, not more than 

1.5 

Maximum load current (tripping current), A, not more than 

2.0 

4.2 TECHNICAL DATA OF THE CONTROLLER UNIT 

The controller unit is designed on the same board as the receiver. The controller unit performs 

the following functions: 

  programming of remote controls and control time of the actuator; 

  applying or removing supply voltage to/from the actuator for a specified time on the signals 

of the programmed remote controls; 

  disconnecting the actuator from the power supply unit (protection) when the current 

consumption by the actuator exceeds the preset level; 

  audible signaling of the controller current operations. 

Supply voltage (direct current), V 

 

12 

Current consumption, mA 

 

5

 

Protection tripping current (disconnection of the actuator), A 

2.0

 

Memory capacity of the remote controls, pcs. 

Range of programmed open lock time, s 

1-15 

4.3 TECHNICAL DATA OF THE RECEIVER 

Supply voltage (direct current), V 

 

12 

Current consumption, mA 

 

2

 

Operating frequency, MHz 

433.92

 

Sensitivity, µV 

Reception range of signals from the remote control Promix-CR.TX.01 (in 
direct visibility and absence of interference), m, not less than 

30 

Summary of Contents for RDS.01

Page 1: ...eiver and controller unit are designed as a single unit controller Promix CR RX 03 hereinafter the controller The receiver of the controller receives control signals of remote controls Promix CR TX 01 The power supply unit of the controller is used to control the connected actuators 2 DELIVERY SET Controller Promix CR RX 03 1 pc Remote control Promix CR TX 01 with a battery 2 pcs Operating manual ...

Page 2: ...erforms the following functions programming of remote controls and control time of the actuator applying or removing supply voltage to from the actuator for a specified time on the signals of the programmed remote controls disconnecting the actuator from the power supply unit protection when the current consumption by the actuator exceeds the preset level audible signaling of the controller curren...

Page 3: ...ontrol Promix CR TX 01 it sends a unique code via a radio channel The controller Promix CR RX 03 receives the sent code and if this code is recorded in the controller memory see Section 7 activates its output contact for the programmed time the supply voltage is applied to or removed from the actuator what is accompanied by a continuous beep signal If the current in the circuit of the actuator exc...

Page 4: ...open state when there is no supply voltage and in the closed state when the supply voltage is applied A normally closed actuator is in the closed state when there is no supply voltage and in the open state when supply voltage is applied Position 3 programming of the controller 7 PROGRAMMING THE CONTROLLER The supplied remote controls are already recorded in the controller memory The factory settin...

Page 5: ...roller emits double short beeps during which the programming is carried out 7 Pressing the button of the programmed remote control increases the open lock time by 1 second The set time in seconds corresponds to the number of beeps 8 If no action is performed during 5 seconds the controller switches from the programming mode into the operating mode confirming it with three beeps 9 Determine the typ...

Page 6: ...s per GOST R IEC 60065 2009 The insulation strength between the current carrying circuits of the mains supply and the secondary circuits with a low voltage complete device must withstand an AC voltage of 3750V of practically sinusoidal form with a frequency of 50 1 Hz The electrical insulation resistance between the current carrying circuits of the mains supply and the secondary circuits depending...

Page 7: ...omponents and units free of charge Costs of delivery to and from the place of repair shall be borne by the Buyer Warranty liabilities do not cover any defects and damages caused by Improper maintenance by the Buyer Use of the products under conditions that do not comply with the operation requirements Mechanical damages or disassembly of the products by the Buyer Non observance of the transportati...

Reviews: