Managing the Pegasus R4i
Pegasus R4i Product Manual
To migrate a logical drive:
1. Click on the
Background Activities
icon.
The list of background activities appears.
2. Mouse-over Migrate and click the
Start
button.
3. In the
Select Disk Array
dropdown menu, choose the source disk array.
4. In the
Select Physical Drives
diagram, click the drives to add them to your array.
The ID numbers of the chosen drives appear in the field below the diagram.
5. Click the
Next
button.
6. Check the box next to the logical drive you want to modify.
7. From the dropdown menu, choose a
target RAID level
.
The choice of RAID levels depends the number of physical drives in the disk array. See the Note
below.
8. In the
Capacity
field, accept the current capacity.
Or check the
Expand Capacity
box and enter a greater capacity and size in MB, GB or TB.
If there is capacity remaining, you can create an additional logical drive.
9. Click the
Next
button.
The logical drive ID numbers, with the original and target RAID levels and capacities are shown
10.
To accept the proposed target values, type “Confirm” and click the
Confirm
button.
Migration - choose RAID