FastCheck
TM
Monitoring Utility
Controller Channel Information
Left-clicking on a given Channel icon or # in the left pane, will show the Base IO
addresses of the channel in the right pane:
Controller Drive Information
Left-clicking on a given Drive icon or ID in the left pane, will show similar
information categories as the Array Window Drive Information in the right pane:
Status:
(Okay, Bad, Offline, Rebuilding)
Okay: Means the drive is working normally
Bad: A problem has been detected in the drive and the drive taken offline.
Mirrored arrays will continue to function without the drive. Striped
and Spanning arrays will go offline when a drive fails. In this case,
you have likely lost data. Fix/replace the drive that has failed, then
restore data from a backup source.
Offline: Drives that are NOT identified as “bad” may be taken offline if part
of a Striping or Spanning array containing a “bad” drive. These drives
do NOT need to be replaced, however.
5-12
Summary of Contents for FastTRAK66
Page 9: ...Introduction ThisPageIntentionallyLeftBlank ...
Page 17: ...Hardware Installation ThisPageIntentionallyLeftBlank ...
Page 45: ...FastCheckTM Monitoring Utility ThisPageIntentionallyLeftBlank ...
Page 57: ...Operating System Installation THIS PAGE LEFTINTENTIONALLYBLANK ...