3 - 15
Adjustment
In
s
p
ect
ion and
Ad
ju
s
tme
n
t
15.Adjustment of the Presser Bar Height
• The gap between the top surface of the needle plate A and the bottom surface of the presser foot should be
6.0 to 6.5 mm.
1
Attach a J presser foot, lower the presser lever, and attach a cover.
2
Raise the presser lifter.
3
Turn the pulley until the feed dog is lowered below the needle plate A.
4
Loosen the screw (Set screw, socket, CP, M 5
×
8) on the presser bar clamp assembly.
5
Adjust the presser bar height so that the gap between the upper surface of the needle plate A and the bottom
surface of the presser foot is 6.0 to 6.5 mm.
6
Tighten the screw (Set screw, socket, CP, M 5
×
8) on the presser bar clamp assembly.
6.0 - 6.5mm
Upper surface of
needle plate
Set screw, socket
(CP) M5
×
8
www.promelectroavtomat.ru