VIII. Appendix II: Research and Forensic Applications of the Maxwell
®
16 System
This section of the Technical Manual discusses use of the Maxwell
®
16 System for Research and Forensic
applications. Operation of the instrument in Research and Forensic modes, or with kits other than
Cat.# AS1015, has not been demonstrated to comply with EU Directive 98/79/EC on in vitro diagnostic
medical devices.
The Maxwell
®
16 Clinical Instrument (Cat.# AS2050) i
s supplied configured for use in clinical mode with SEV
(Standard Elution Volume)
hardware
. When used for research or forensic applications, the instrument may
be configured with SEV or LEV (Low Elution Volume) hardware for different elution volume preferences.
See Section VIII.B for instructions on how to configure your instrument in SEV or LEV format.
VIII.A. Operational Mode Setup Requirements
The Maxwell
®
16 Instrument has multiple operational modes, depending on the procedure and the
purification kit used. Table 2 lists the hardware configuration and operational mode requirements for
the Maxwell
®
16 Purification Kits. Please refer to the Technical Manual supplied with your specific
purification kit for further information on the operational mode required.
Table 2. Hardware Configuration and Operational Mode Setup Requirements for Research and
Forensic Applications.
Please ensure that you select the operational mode that is required for your hardware configuration. Failure to
use the correct operational mode and hardware configuration will cause damage to the instrument
.
Maxwell
®
16 Kit
Purification
Procedure
Firmware
Operational Mode
Hardware
Configuration
Maxwell
®
16 gDNA
Purification Kits
(Cat.# AS1010, AS1020, AS1030)
gDNA
Research
(Rsch)
Standard Elution
Volume
(SEV)
Maxwell
®
16 Polyhistidine
Protein Purification Kit (Cat.#
AS1060)
Polyhistidine-
Tagged Protein
Research
(Rsch)
Standard Elution
Volume
(SEV)
Maxwell
®
16 Total RNA
Purification Kit
(Cat.# AS1050)
Total RNA
Research
(Rsch)
Standard Elution
Volume
(SEV)
Maxwell
®
16 LEV Total RNA
Purification Kits
(Cat.# AS1220, AS1225)
Total RNA
Research
(Rsch)
Low Elution Volume
(LEV)
DNA IQ™ Reference Sample
Kit for Maxwell
®
16
(Cat.# AS1040)
Forensic gDNA
Reference Samples
Forensic
(Fnsc)
Standard Elution
Volume
(SEV)
DNA IQ™ Casework Sample
Kit for Maxwell
®
16 LEV
(Cat.# AS1210)
Forensic gDNA
Casework Samples
Forensic
(Fnsc)
Low Elution Volume
(LEV)
!
tm300.0208_Corrected.qxp 3/11/2008 10:41 AM Page 27