Beta Draft Confidential
Sensor Settings Page
Basic Series Network Thermostat Configuration Guide, Release 3.0
3-37
Part No. 600-01000-201, Rev. 1
Sensor Averaging
Select
Enable
or
Disable
to indicate if this remote thermal
sensor is to participate in the algebraic averaging of either or
both of the thermostat (local) sensor or the remaining Remote
Sensor. This parameter is visible only if the
Remote Sensor
#1/#2 State
is enabled. (See
Zone Temperature (page 3-10)
.)
Disable
(default) – Algebraic thermal averaging is disabled.
Enable
–
Remote Sensor #1/#2
is included in the thermal
averaging calculations. The Zone temperature now reflects
the average temperature of the averaged measurements.
Sensor Correction
Select the calibration or temperature offset compensation for this
remote thermal sensor. Offset adjustments are added or
subtracted from the actual temperature read from this sensor and
displayed as the apparent temperature. This apparent
temperature is available for averaging with the other sensors if
Sensor Averaging
is selected.
-5
°
F (-2.8
°
C) t5
°
F (2.8
°
C)
– Offset temperature in
degrees Fahrenheit or Celsius increments. The default is
0
.
Table 3-7 Sensor Settings Field Descriptions (Continued)
Field
Description