19
TYPE 6
Input of sensors, outlet by two relays (open -
close).
Special type to work on windows with lathe so
that the natural ventilation can be made.
When the temperature is higher than the
reference, some timings are made, one of stop and
another of opening.
The same happens to close, when the
temperature is lower than the reference minus the
differential.
CONSULT
P01 VTNA-0 E 24.8 ºC
S Open
PROGRAMME
P01 VTNA-0 C0
Reference= 24.0 ºC
Differential= 02.0 ºC
Tim. Open= 05 s
Pause Open = 128 s
Tim. Close= 100 s
Pause Close= 100s
Manual (Yes/no)= No
CURVE1
P01 VTNA-0 C1Pto1
Pos=000
Ref=24.8 ºC
Pos=045
Ref=21.3 ºC
Pos=000
Ref=000 ºC
Pos=000
Ref=000 ºC
CONFIGURATION
P01 VTNA-0
Type of working= 6
Text= 05
Number= 0
Num. of inputs= 8 7
Num. of outlet= 04(5)
Conditioning Pro.= 00
Affects in code= 00
RECORD
VTNA-0 21/06
24.9
23.4
21.7 ºC
High alarm
20.0
REFERENCE
15.0
DIFFERENTIAL
10.0
Low
alarm
5.0
OPEN
STOP
CLOSE
Summary of Contents for AMBITROL 100