The two 5 Meter / 15 Ft electrical cables
supplied are pre-wired in factory on the electric
drive motor. The end of the two cables must
be connected onto a relay box (PROFURL
option). It allows the rotation of the motor to
be reversed for furling/unfurling.
The relay box should be fitted inside the boat
in a dry area.
A control box should be connected by cable
to the relay box, to allow operating the system
(normally from the cockpit).
WIRING OF ELECTRIC SYSTEMS
(NDE series)
The electrical circuit has to be protected with the special circuit breaker supplied with the system,
fitted as shown on drawing.
In case the boat has a metal hull, or is being used for commercial sailing in some countries, the circuit
breaker should be specified as bi-polar, and ordered as an option at PROFURL.
PLEASE MAKE SURE THE ANCHOR CHAIN OR ANY OTHER LINE WILL NOT
Extra protection over the wires running above
CAUT
The gear motor has been w
Without the special tools and knowledge of the procedure to o
Any attempt to open the gear motor without prior
10
CONTROL BOX
(not supplied)
OPTIONAL
CIRCUIT BREAKER
(if necessary)
MAIN SWITCH
(not supplied)
BATTERY
MAGNETO-THERMIC
CIRCUIT BREAKER
(supplied)
RELAY
BOX
(supplied)
Model
NDE 42
NDE 52
Power of motor
Outside diameter of the electrical wires
(supplied)
12V
25 sq mm
25 sq mm
24V
5 mm (
3/16”
)
5 mm (
3/16”
)
12V
8.5 mm (
11/32”
)
8.5 mm (
11/32”
)
24V
16 sq mm
16 sq mm
Minimal power supply wires section
12V
700 W
700 W
24V
800 W
800 W