- 5 -
Condition:
Vacuum Breaker Leaking
If the Vacuum Breaker (E) is leaking, it is likely that the water pressure is insufficient
or that there is insufficient flow due to a plugged inlet screen in the lower Supply
Shank. The recommended static pressure for the 503 Series is between 20 psi and
125 psi and for the 504 Series between 25 and 125 psi.
Note:
If the trouble-shooting steps listed in this manual do not resolve your problem, contact
FLUSHMATE
®
Consumer Services at 800-533-3460 or email [email protected].
Please be prepared to provide the serial number and date of installation of your
FLUSHMATE
®
system.
WINTERIZING
1. Turn off the water supply valve and flush the toilet to relieve the pressure.
2. Place a bucket under the lower Supply Shank (A) and disconnect the water supply
line, allowing the water to drain into the bucket.
3. Push down on the Actuator and pull it up momentarily to allow air into the vessel.
4. Follow the fixture manufacturer’s instructions for winterizing the bowl.
5. Do not put antifreeze or any other chemical agents in the china holding tank or in
the
FLUSHMATE
®
Tank.
POINTS TO REMEMBER
• When replacing components on the
FLUSHMATE
®
Flushometer-Tank System,
make certain that the water supply valve is turned off and the toilet has been
flushed to relieve pressure in the
FLUSHMATE
®
tank.
• USE OF PETROLEUM-BASED LUBRICANTS OR CORROSIVE CLEANING
PRODUCTS CONTAINING CHLORINE, SUCH AS HOUSEHOLD BLEACH,
DROP-IN BLOCKS OR TABLETS, OR DISINFECTANTS THAT ARE APPLIED
INSIDE THE CHINA HOLDING TANK WILL VOID YOUR
FLUSHMATE
®
WARRANTY.
•
FLUSHMATE
®
Flushometer-Tank Systems are designed to be used with cold water.
• The Flush Valve Cartridge can be removed by inserting the handles of a pair of
pliers into the top of the Flush Valve Cartridge and turning counterclockwise.
• A small amount of water may be present in the bottom of the china holding tank.
The potential for odor can be eliminated by adding a cup of white vinegar to the
china holding tank. The white vinegar will act as natural disinfectant.
• Your water pressure is adequate if your water supply line will yield one or more
gallons of water within thirty (30) seconds.
• Replacement parts are readily available by contacting Consumer Services at
800-533-3460 or by visiting the “Where to Buy” section of our website,
www.flushmate.com, or purchase online at www.eflushmate.com.
If you would like additional information or require technical assistance, please contact
FLUSHMATE
®
Consumer Services at 800-533-3460, or visit our website,
www.flushmate.com. For faster service, please be prepared to provide the serial
number and date of installation of your
FLUSHMATE
®
system.
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16