PLEASE READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO MAKE 

ANY ADJUSTMENTS OR REPAIRS.

WARNING:
• When replacing components on the 

FLUSHMATE

®

Flushometer-Tank System, make certain that the

water supply valve is turned off and the toilet has been flushed to relieve pressure in the
FLUSHMATE

®

tank.

• USE OF PETROLEUM-BASED LUBRICANTS OR CORROSIVE CLEANING PRODUCTS CONTAINING

CHLORINE, SUCH AS HOUSEHOLD BLEACH, DROP-IN BLOCKS OR TABLETS, OR
DISINFECTANTS, THAT ARE APPLIED INSIDE THE CHINA HOLDING TANK WILL VOID YOUR
FLUSHMATE

®

WARRANTY. The exterior of the tank and the entire bowl can be cleaned following

the manufacturer’s recommendations or in the same fashion as any other toilet.

• 

FLUSHMATE

®

Flushometer-Tank Systems are designed to be used with a cold water supply only

and use of a tempered or hot water supply will void your warranty.

TROUBLESHOOTING

A) Condition: 

Water runs and will not shut off

A run-on condition may be caused by insufficient water pressure, an improperly
adjusted Flush Valve Cartridge, or a clogged inlet screen. Refer to “Installation
Requirements” for recommended minimum pressure. (See “Points to Remember” for
a simple method to determine whether your water pressure is adequate). Check water
pressure, marginal pressure can cause any of these conditions. If sufficient water
pressure has been verified and the toilet continues to run-on, the following steps may
be required:

1. Make sure the water supply valve is fully open.

2. Check the Actuator adjustment. The Flush Rod (I) or push button should not

interfere with the Actuator. The proper clearance should be approximately 1/8”
when the push button or flush-handle is stationary. On push button type fixtures,
loosen the setscrew on the Actuator (see F on the component list) and rotate the
Actuator up (counterclockwise) or down (clockwise) until the proper clearance is
obtained. For flush-handle fixtures, observe the clearance. 

(See Figure 1)

If

necessary, adjust the Actuator to allow for proper clearance. When proper
clearance is obtained, tighten the setscrew.

3. Check Inlet Screen

a. Turn off the water supply valve.

b. Flush the toilet to relieve the pressure.

c. Disconnect the water supply line from the Supply Shank (A). 

(See Figure 6)

d. Examine the inlet screen and remove anything that may be blocking the flow of

water into the 

FLUSHMATE

®

tank. The inlet screen can be removed by inserting

a small pointed object (such as a large paperclip or the blade of a penknife) into
the lower Supply Shank and working the inlet screen loose. 

(See Figures 7a, 7b,

7c)

Reinstall the inlet screen by pushing it upward into the Supply Shank with

your fingertip. 

(See Figure 7d)

e. Reattach water supply line and fully open water supply valve. Test setup by

flushing toilet.

4. Remove, examine, and reinstall the Flush Valve Cartridge (3).

a. Turn off the water supply valve and flush the toilet to relieve the pressure.

b. On flush-handle fixtures, disengage the Flush Rod from the handle linkage and

flip it away from the Flush Valve Cartridge. It is not necessary to loosen the
retainer clips. 

(See Figure 3)

Remove the Flush Valve Cartridge using the

handles of a pair of pliers. 

(See Figure 2)

. Turn the Flush Valve Cartridge

counterclockwise until you can lift it out of the 

FLUSHMATE

®

tank. 

Summary of Contents for PF1612PA

Page 1: ...Owner s Operation Installation Guide FLUSHMATE A Division of Sloan Valve Company PF1612PA...

Page 2: ...OSIVOS QUE CONTENGAN CLORO TALES COMO EL BLANQUEADOR CASERO BLOQUES O TABLETAS PARA EL AGUA O DESINFECTANTES QUE SE APLIQUEN DENTRO DEL TANQUE DE DEP SITO DE PORCELANA ANULAR N LA GARANT A DE SU FLUSH...

Page 3: ...from the water supply line It is important to have sufficient pressure at the supply The minimum line pressure for a 1 6 gpf system is 20 psi and 25 psi for 1 0 gpf All pressure assist toilets get the...

Page 4: ...ner presi n suficiente en el suministro La presi n m nima de la tuber a de agua para un sistema de 1 6 gpf es de 20 psi y de 25 psi para un dispositivo de 1 0 gpf Todos los excusados asistidos por pre...

Page 5: ...avoir suffisamment de pression d alimentation La pression du tuyau d alimentation pour un syst me 1 6 gpc doit tre d au moins 20 psi et d au moins 25 psi pour 1 gpc Toutes les toilettes pression tiren...

Page 6: ...jours vacuer l eau des tuyaux d alimentation en eau avant de les raccorder Une fois l installation termin e vous devrez r gler l actionneur de la cartouche F Pour le r gler assurez vous d avoir ouvert...

Page 7: ...cartouche du robinet de chasse ins rez les manches d une paire de pinces dans le haut de la cartouche du robinet de chasse puis tournez dans le sens antihoraire Il est possible qu une petite quantit...

Page 8: ...504 Tank Service Manual FLUSHMATE Flushometer Tank System PF1612PA...

Page 9: ...equired for flush handle fixture Tighten setscrew after adjusting the Actuator Additional notes Should your toilet continuously run on after installing refer to section 1 under Troubleshooting You may...

Page 10: ...d I or push button should not interfere with the Actuator The proper clearance should be approximately 1 8 when the push button or flush handle is stationary On push button type fixtures loosen the se...

Page 11: ...cking the flow of water into the FLUSHMATE tank The inlet screen can be removed by inserting a pointed object such as a large paperclip or the blade of a penknife into the lower Supply Shank and worki...

Page 12: ...et has been flushed to relieve pressure in the FLUSHMATE tank USE OF PETROLEUM BASED LUBRICANTS OR CORROSIVE CLEANING PRODUCTS CONTAINING CHLORINE SUCH AS HOUSEHOLD BLEACH DROP IN BLOCKS OR TABLETS OR...

Page 13: ...d representatives of the Company or by others upon specific approval by the Company Unauthorized repairs or alterations shall specifically void the warranty 4 USE OF PETROLEUM BASED LUBRICANTS OR CORR...

Reviews: