Read the present instruction manual carefully before proceed-
ing with installation works.
Compliance with the manual requirements ensures reliable op-
eration and long service life of the product. Keep the instruc-
tion manual available as long as you use the product.
You may need to re-read the information on the product servic-
ing.
Delivery set
1.
Fan - 1 item;
2. Screws and dowels - 4 items;
3. Plastic
screwdriver (only for the models with a timer and
humidity sensor) - 1 item;
4. Instruction
manual;
5. Packing
box.
Brief description
The product described herein is an axial fan for supply and
exhaust ventilation of small and medium-sized premises. The
fan is made of white plastic. The fan is designed for connection
to 100 mm air ducts.
Due to constant improvements the design of some models
may slightly differ from those ones described in this instruction
manual.
Operation guidelines
The fan is designed for connection to AC 220-240 V, 50 Hz
power mains.
The fan is designed for continuous operation always connected
to power mains.
Air flow direction in the system must match the pointer direction
on the fan casing.
Ingress protection rating against access to hazardous parts and
water ingress
–
IP45.
The fan is rated for operation at the ambient temperature rang-
ing from +1 °C up to +45 °C.
The fan requires no grounding.
Mounting
The fan is designed for ceiling or wall mounting and is con-
nected to a ventilation shaft or an air duct of 100 mm diameter,
Fig.1.1.
In case of vertical mounting of the fan must be protected
against ingress of rainfalls and condensate inside the fan. Fan
installation with direct air discharge upwards is not allowed,
Fig.1.2.
Fan mounting sequence is shown in Fig.2.
Electrical connections
Electrical connection diagramm is shown in Fig.3.1 - 3.2.
L
- phase;
N
- 0;
LT
- timer control line;
QF
- automatic circuit breaker;
S
- external switch.
WARNING!
The timer circuit is under mains voltage. Disconnect the fan
from power mains prior to any adjustment operations. The fan
delivery set includes a specially designed plastic screwdriver
for fan settings adjustments. Use the screwdriver to change the
turn-off delay time or the humidity set point (Fig.3.3).
Do not use a metal screwdriver, knife, etc. for adjustment opera-
tions not to damage the circuit board.
Electronic operating logic
Fan is equipped with an electronic processor (ТН) with perma-
nent humidity level monitoring function that prevents conden-
sate generation. The fan switches automatically on as the rela-
tive humidity in the premise reaches the preset set point value
adjustable from 60 to 90% and continues operating within 2 to
30 minutes according to the timer setting until the humidity level
will not reach set point.
To adjust the humidity set point turn the control knob of H regu-
lator clockwise to increase the humidity sensor set point and
counterclockwise to decrease it (Fig.3.3).
The fan may operate in timer mode if it is connected to power
mains through the light switch. After the light is off the fan oper-
ates within the set time period, from 2 to 30 minutes.
To adjust the turn-on delay time turn the control knob of the
regulator clockwise to increase the set point and counterclock-
wise to decrease it (Fig.3.3).
Maintenance
The fan maintenance periodicity is at least once per 6 months.
Maintenance sequence is shown in Fig.4.
WARNING!
Avoid water dripping on the electric components.
Transportation and storage rules
Transport the product by any transportation vehicle in the manu-
facturer’s original package. Store the delivered product in the
manufacturer’s original packing box in a dry ventilated premise
with the temperature range from +5
0
C up to + 40
0
C and rela-
tive humidity less than 80%.
The storage environment must not contain dust, acid or alkali
vapours that may cause corrosion of the product parts.