MODELS   QTXEN050C • QTXEN090C • QTXEN110C • QTXEN150C

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you

have questions, contact the manufacturer at the address or telephone
number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards, and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI

(Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).

8. This unit must be grounded.

CAUTION  

!

1. For general ventilating use only. Do not use to exhaust hazardous or

explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced blower

wheels, keep drywall spray, construction dust, etc. off power unit.

3. Please read specification label on product for further information

and requirements.

QTXEN SERIES

ULTRA SILENT

TM

VENTILATION FAN

READ AND SAVE THESE INSTRUCTIONS

INSTALLER: Leave this manual with the homeowner • HOMEOWNER: Cleaning and Maintenance on page 3

OPERATION

Use an on/off switch or speed control to operate this ventilator. See
“Connect Wiring” for details.

TYPICAL INSTALLATIONS

Housing mounted to 

I

-joists.

Use 

I

-joist spacer block (provided).

Housing mounted to joists.

Housing mounted to truss.

Summary of Contents for QTXEN050C

Page 1: ...ing equipment manufacturer s guideline and safety standards and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit ceiling installation only...

Page 2: ...osed 4 Install 6 inch 152 4 mm round ductwork Connect 6 inch 152 4 mm round ductwork to damper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork connections to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact the bottom of the joist...

Page 3: ...into slots on each side of housing 8 Push grille against ceiling 6 Finish ceiling Install ceiling material Cut out around housing INSTALL GRILLE CLEANING MAINTENANCE For quiet and efficient operation long life and attractive appearance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearing...

Page 4: ...SE During this three year period Broan NuTone Canada will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES BULBS OR BATTERIES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service...

Page 5: ...conduit doivent toujours être raccordés à un évent extérieur 7 Si cet appareil doit être installé au dessus d une douche ou d une baignoire il doit être conçu pour cette application et doit être raccordé à une branche de circuit protégée par un disjoncteur différentiel installation au plafond seulement 8 Cet appareil doit être mis à la terre ATTENTION 1 Pour une utilisation de ventilation générale...

Page 6: ... Rallonger le conduit jusqu à un évent extérieur à travers un toit ou un mur Fixer tous les raccords de conduit à l aide de ruban pour les assujettir et pour qu ils soient étanches et qu ils restent en place INSTALLATION DU BOÎTIER ET DU CONDUIT 2 Monter le boîtier sur les solives Maintenir le boîtier en place de manière à ce que les languettes du boîtier entrent en contact avec la partie inférieu...

Page 7: ...riau autour du boîtier FIXATION DE LA GRILLE UTILISATION ET ENTRETIEN Pour assurer un fonctionnement silencieux et efficace de l appareil en prolonger la durée utile et en conserver l apparence abaisser ou enlever la grille puis nettoyez l intérieur de l appareil à l aide d un aspirateur muni de la brosse à épousseter Le moteur est lubrifié à vie Aucune lubrification n est nécessaire Si les roulem...

Page 8: ... BROAN NUTONE CANADA DOIT ÊTRE LA SEULE OBLIGATION EXCLUSIVE EN VERTU DE CETTE GARANTIE BROAN NUTONE CANADA NE DOIT PAS ÊTRE TENUE RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SPÉCIAUX SURVENANT À CAUSE DE L UTILISATION OU DE LA PERFORMANCE DE SES PRODUITS OU EN RAPPORT AVEC CELLES CI Cette garantie annule toutes les garanties précédentes Pour obtenir le service après vente aux fins de la garanti...

Reviews: