V.6.9.2.
Configuring SIP
Any SIP call actor requires the setting of two IP ports; one for the signalling
messages and another one for the actual audio data stream. By default the
signalling port 5060 and audio port 5004 are provided complying to the
corresponding standards for SIP and RTP (RFC’s 3261 and 3550). The
communication mate must agree with both port numbers to make a call possible.