Always  run  heater  with  control  knob  at  Pilot  or  on  locked  positions.  Never  set  control  knob  between  locked 
positions. Poor combustion and higher levels of carbon monoxide may result. 

 
8. 

Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the 
room heater and to replace any part of the control system and any gas control which has been under water. 

 
9. 

Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair 
heater. 

 
10.  Operating heater above elevations of 4,500 feet could cause pilot outage. 
 
11.  To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 
 
12.  This heater should not be installed in a bedroom or bathroom. 
 
13.  Do not use this heater as a wood-burning heater. Use only the logs provided with the heater. 
 
14.  To prevent the creation of soot, follow the instructions in 

Care and Maintenance

 (page 20). 

 
15.  Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can 

cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After 
servicing, always replace screen before operating heater. 

 
16.  This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service 

person.  Note:  During  initial  operation,  slight  smoking  could  occur  due  to  log  curing  and  the  heater  burning 
manufacturing residues. 

 
 

QUALIFIED INSTALLING AGENCY 

Installation  and  replacement  of  gas  piping,  gas  utilization  equipment  or  accessories  and  repair  and  servicing  of 
equipment  shall  be  performed  only  by  a  qualified  agency.  The  term 

qualified  agency

  means  any  individual,  firm, 

corporation, or company that either in person or through a representative is engaged in and is responsible for:  

a)  Installing, testing, or replacing gas piping or 

b)  Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar 

with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for BD23TCC-2-LO

Page 1: ...TY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion an...

Page 2: ...x 23 000 BTU Hr 23 000 BTU Hr 23 000 BTU Hr 23 000 BTU Hr Input Min 14 000 BTU Hr 19 000 BTU Hr 14 000 BTU Hr 19 000 BTU Hr Gas Type Natural LP Propane Natural LP Propane Ignition Electronic Piezo Ele...

Page 3: ...s that alter burner flame patterns which can cause sooting WARNING Do not use a blower insert heat exchange insert or other accessory not approved for use with this heater Due to high temperatures the...

Page 4: ...Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting Do not add lava rock around base Rock and debris could fall into the control ar...

Page 5: ...ust be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy o...

Page 6: ...approximately one 1 ounce 30ml of water for every 1 000 BTUs 3kWs of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an enti...

Page 7: ...of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are...

Page 8: ...mum the space can support BTU hr actual amount of BTU hr used Example 51 200 BTU hr maximum the space can support 56 000 BTU hr actual amount of BTU hr used The space in the above example is a confine...

Page 9: ...permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors see figure 3 These spaces incl...

Page 10: ...etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free...

Page 11: ...ed equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never c...

Page 12: ...Hold gas regulator with wrench when connecting into gas piping and or fittings NG Models 5 in to 10 5 in W C Gas supplier provide external regulator for natural gas Purchase the optional CSA design c...

Page 13: ...the width of a quarter and turn knob counterclockwise until the knob locks into the LP position see Figure 10 Selection valve must be locked into either the LP position or the NG position 3 Rotate and...

Page 14: ...system Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected...

Page 15: ...structions in this manual Flames contacting logs will create soot Figure 13 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Figure13 It is very important to install the...

Page 16: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 17: ...ignitor button until pilot lights Note If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match 7 Keep control knob press...

Page 18: ...rward 2 Follow steps 1 through 5 under Lighting Instructions 3 With Control Knob in PILOT position strike match and hold near pilot Press in Control Knob pilot should light 4 Keep Control Knob pressed...

Page 19: ...ting page 21 23 BURNER FLAME PATTERN Figure 24 shows a correct burner flame pattern Figure 25 shows an incorrect burner flame pattern If pilot flame pattern is incorrect then Turn heater off see To Tu...

Page 20: ...no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could d...

Page 21: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrod...

Page 22: ...tomer service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and maintenance Pa...

Page 23: ...furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products He...

Page 24: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Page 25: ...1 FBB28D01 B Burner Assembly 1 2 NDD0308 400 DF ODS 1 3 SIT545 200 T Stat Valve Assembly 1 4 AL092 01 PIMSC1 01 Piezo Ignitor 1 5 RV83FI 4 9 DF Regulator 1 6 YDF06 BD23T Gas Selection Valve Assembly 1...

Page 26: ...ront Panel Left 1 1 6 BD230T104 Lower Front Panel Right 1 1 7 BD230T109 Door 1 1 8 BD230T005 Decorative Trim Assembly 1 1 9 BD230T003 Firebox Assembly 1 1 10 BD230T004 Louver Assembly 1 1 11 BD230T201...

Page 27: ...27 Printed in China...

Reviews: