background image

CIRCUIT PROTECTION 
 
All 

Wobblelight

®

 models are equipped with an externally re-settable circuit breaker located beneath the power switch.  The breaker will trip when the total amperage load on 

Wobblelight

®

 exceeds 12 amps.  If the breaker trips, the lamp circuit and the accessory outlet will be immediately de-energized.  The following steps should be taken in the event of 

a circuit breaker trip: 
 

1. Disconnect 

the 

Wobblelight

®

 with the tripped circuit breaker from the power source and turn the power switch to the “off” position.

 

2. 

Insure that the power source is 120-volt, 60-Hz, 15-amp service.

 

3. 

Determine if the Wobblelight

®

 accessory plug was electrically overloaded by checking the number and type of all downstream electrical devices that are plugged into the 

accessory outlet.  

 

4. 

If it is possible that the labeled amperage rating on the accessory outlet was exceeded, disconnect all electrical devices from the accessory outlet and reset the circuit 
breaker by pushing the tab back into the breaker until it clicks into position.

 

5. Reconnect 

the 

Wobblelight

®

 to the power source and turn the power switch on.

 

6. 

If the Wobblelight

®

 does not illuminate, turn the unit off, disconnect from the power source and take out of service (remember to allow up to 10 minutes for a metal halide 

lamp to restart from hot condition).

 

7. 

If the Wobblelight

®

 illuminates, you can begin to reconnect the electrical devices plugged into the accessory outlet one at a time.  Be aware of the total amp load being 

placed on the accessory outlet.

 

8.  If the circuit breaker trips again, the accessory outlet is likely being overloaded.  Disconnect the 

Wobblelight

®

 from the power source, t

urn the power switch to 

the “off” position and disconnect one or more electrical devices from the accessory outlet. 

9.  Reset the circuit breaker and repeat steps 5-7. 

10. 

If the circuit breaker continues to trip and you are certain that the accessory outlet amp rating is not being exceeded (or if nothing is connected to the 
accessory plug), disconnect the 

Wobblelight

®

 and take it out of service.  

11. Contact Wobblelight

®

 customer service or your local authorized service center for repairs and/or replacement parts. 

12. Wobblelight

®

 models supplied with Metal Halide lamps are protected with an internal fast-blow glass fuse.  If this fuse blows then the Wobblelight

®

 transformer, capacitor 

and lamp must all be replaced by an authorized electrician. 

 

CAUTION:

  The Wobblelight

®

 circuit breaker and fuse are important safety features. 

 

x

 

Do not remove, alter or disable the Wobblelight

®

 circuit breaker and fuse. 

x

 

Do not operate Wobblelight

®

 without the circuit breaker and fuse in place. 

x

 

Do not use tape or similar means to try holding the breaker in a permanent “reset” position.  The breaker will still trip. 

x

 

Any improper use or modification of the circuit breaker or fuse will void the warranty. 

 

 
QUESTIONS OR PROBLEMS? 

Call ProBuilt Professional Lighting Customer Service and Technical Support at 877-707-0800 (Monday-Friday from 8:30 am until 5:00 pm Central 
time) or e-mail to 

[email protected]

 anytime. 

 
 
Wobblelight

®

 LIMITED WARRANTY INFORMATION 

 

Manufacturer’s Limited Warranty 

Wobblelight® products manufactured by ProBuilt Professional Lighting LLC are warranted against defects in material and workmanship for a period of one year from date of 
purchase.  ProBuilt Professional Lighting LLC will repair or replace any defects due to faulty materials or workmanship during the warranty period.  Proof of purchase and 
compliance with all product use information is required.  A restocking fee of 15% will be charged for all non-defective goods.  Shipment or delivery of defective products for warranty 
repair or replacement is the responsibility of the purchaser. 

Summary of Contents for Wobblelight 175-watt Metal Halide

Page 1: ...Click Here To View Item at www GapPower com...

Page 2: ...xtended period of time after Wobblelight unit has been turned off and can continue to cause burns x DO NOT attempt to remove the protective lens to change bulbs unless the Wobblelight unit is disconne...

Page 3: ...ube Metal halide arc tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as ballast failure or misapplication An a...

Page 4: ...8 minutes to achieve full brightness Metal halide lamps which are shut off and then turned back on while still hot may require 5 10 minutes to restart SAVE THESE INSTRUCTIONS Specific Precautions for...

Page 5: ...cap assembly by aligning the five mounting holes with the five mounting nuts note the dome handle should be aligned with the power switch 6 Re install the five mounting screws do not over tighten SAVE...

Page 6: ...2 Amps x To avoid possible electrical overload Wobblelight should only be plugged into 120 volt 60 Hz electrical service which is protected by a circuit breaker of 15 amps or less x DO NOT overload th...

Page 7: ...y outlet 9 Reset the circuit breaker and repeat steps 5 7 10 If the circuit breaker continues to trip and you are certain that the accessory outlet amp rating is not being exceeded or if nothing is co...

Page 8: ...ind to any products items or personal or other property caused by use of the Wobblelight product that is contrary to the instructions or documentation accompanying your Wobblelight product Costs of sh...

Reviews: