background image

 

x

 Sylvania 

Metalarc

®

 M175/U/ET18, Eiko ArcMaster

®

 MH175/U/ED28 

x

 Sylvania 

Metalarc

®

 M400/U/ET18, Eiko ArcMaster

®

 MH400/U/ED28 

 

IV. LAMP 

INSTALLATION 

 

a. Disconnect 

Wobblelight

®

 from power source and turn off switch. 

b.  Allow dome and lamp to cool completely. 
c. Remove 

the 

Wobblelight

®

 dome / cap assembly by removing the five mounting screws. 

d.  Screw lamp firmly but not forcibly into socket in order to avoid breakage. 
e.  Tighten bulb until it is secure in the socket – do not over tighten. 
f. Reinstall 

the 

Wobblelight

®

 dome / cap assembly by aligning the five mounting holes with the five mounting nuts (note the dome handle should be 

aligned with the power switch). 

g.  Re-install the five mounting screws – do not over tighten. 

 

V. 

BROKEN ARC-TUBE:  Take care in handling and disposing of metal halide lamps.  If arc-tube is broken, avoid skin contact with any of the contents 
and fragments.  See manufacturer’s Material Safety Data Sheet for further details. 

 

LAMP CONTAINS MERCURY:

  Manage in accordance with all applicable disposal laws.  See 

www.lamprecycle.org

 

 

OPERATING NOTE:

  Metal halide lamps may require up to 60 seconds to initially start from cold condition, and another 6-8 minutes to achieve full brightness.  

Metal halide lamps which are shut off and then turned back on while still hot may require 5-10 minutes to restart. 

 

SAVE THESE INSTRUCTIONS  
 
 
 

Specific Precautions for Halogen Units 

500-watt Halogen Wobblelight

®

 

 

CAUTION!

 

 
The following instructions must be followed in order to avoid the risk of personal injury, property damage and poor lamp performance. 
 

x

 

The halogen lamp contains an inner capsule that operates at high internal pressure and at high surface temperature and may unexpectedly shatter.  The 
outer glass bulb is not designed to contain hot flying particles in the unlikely event of a capsule rupture.  Therefore, only operate lamp in the enclosed 
Wobblelight

®

 fixture with dome and cap installed and free of damage. 

x

 

To avoid the possibility of fire, do not operate the halogen lamp close to materials that are combustible or affected by heat or drying. 

x

 

To avoid risk of serious eye injury from the intense light, do not stare at the operating lamp. 

x

 

To avoid electric shock, turn off power and let lamp cool completely before attempting replacement. 

x

 

To avoid skin burns, allow lamp to cool completely before handling. 

x

 

For safe and proper halogen lamp operation, operate lamp at rated voltage and wattage.  Operation above rated voltage increases internal pressure and, 
thus increasing the risk of rupture. 

Summary of Contents for Wobblelight 175-watt Metal Halide

Page 1: ...Click Here To View Item at www GapPower com...

Page 2: ...xtended period of time after Wobblelight unit has been turned off and can continue to cause burns x DO NOT attempt to remove the protective lens to change bulbs unless the Wobblelight unit is disconne...

Page 3: ...ube Metal halide arc tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as ballast failure or misapplication An a...

Page 4: ...8 minutes to achieve full brightness Metal halide lamps which are shut off and then turned back on while still hot may require 5 10 minutes to restart SAVE THESE INSTRUCTIONS Specific Precautions for...

Page 5: ...cap assembly by aligning the five mounting holes with the five mounting nuts note the dome handle should be aligned with the power switch 6 Re install the five mounting screws do not over tighten SAVE...

Page 6: ...2 Amps x To avoid possible electrical overload Wobblelight should only be plugged into 120 volt 60 Hz electrical service which is protected by a circuit breaker of 15 amps or less x DO NOT overload th...

Page 7: ...y outlet 9 Reset the circuit breaker and repeat steps 5 7 10 If the circuit breaker continues to trip and you are certain that the accessory outlet amp rating is not being exceeded or if nothing is co...

Page 8: ...ind to any products items or personal or other property caused by use of the Wobblelight product that is contrary to the instructions or documentation accompanying your Wobblelight product Costs of sh...