background image

x

 

Keep extensions cords dry and use ground fault circuit interrupter (GCFI) devices in accordance with all applicable electrical code requirements. 

x

 

DO NOT operate Wobblelight

®

 units with the protective dome and cap missing or broken.  DO NOT use Wobblelight

®

 units with a broken housing or 

damaged electrical receptacles.  Take any damaged units out of service immediately.  Replacement parts and/or repair services are available from 
Wobblelight

®

 or a local authorized service center. 

x

 

DO NOT exceed the labeled amperage for the Wobblelight

®

 accessory outlet (see Accessory Receptacle Instructions). 

x

 

DO NOT attempt to remove, alter or disable the Wobblelight

®

 circuit breaker. 

x

 

Use only designated replacement bulbs of the appropriate type, shape and wattage. 

x

 

DO NOT expose Wobblelight

®

 to intense heat or sparks from welding slag, cutting torches, metal saws, etc. 

x

 

DO NOT expose Wobblelight

®

 to corrosive chemicals, excessive paint spray or abrasive blasting materials. 

x

 

Disassembly of Wobblelight

®

 will void the warranty.  Contact Wobblelight

®

 or a local authorized service center for repairs and replacement parts. 

 

WARNING:

  Deviation from these instructions may result in the increased risk of fire, electric shock, injury to persons or property damage. 

 

Specific Precautions for Metal Halide Units 

175-watt Metal Halide Wobblelight

®

 

400-watt Metal Halide Wobblelight

®

 

 

WARNING! 

 
The following instructions must be followed in order to avoid the risk of personal injury, property damage and poor lamp performance. 
 

I. 

RUPTURE RISKS:  Metal halide lamps are constructed of an outer glass bulb with an internal arc-tube.  Metal halide arc-tubes operate at high 
pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as ballast failure or 
misapplication.  An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot 
particles.  In the event of such a rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. 

 

TO REDUCE THESE RISKS: 

 

1.  Only operate lamp in the enclosed Wobblelight

®

 fixture with dome and cap installed and free of damage. 

2.  Only operate lamp with compatible ballast (see bulb manufacturer catalog or contact Wobblelight

®

 for specific information). 

3.  Only operate lamp in the upright operating position. 

4.  Lamp must be turned off for a minimum of 15 minutes at least once per week. 

5.  Never expose an operating lamp to moisture such as rain, sleet or snow. 
6.  Replace lamp if outer glass is scratched, cracked or damaged in any way. 
7.  Replace lamp at or before the end of rated life (see bulb manufacturer catalog for rated life). 
8.  To avoid risk of serious eye injury from the intense light, do not stare at the operating lamp. 

 

II. 

ELECTRICAL SHOCK AND BURN HAZARD:  Do not remove or insert lamp while power is on.  If outer glass is broken, shut off power immediately 
and remove lamp after it has completely cooled. 

III. 

ULTRAVIOLET RADIATION EXPSOURE:                  WARNING:  Metal halide lamps can cause skin burn and eye inflammation from shortwave 
ultraviolet radiation if the outer envelope of the lamp is broken or punctured.  Do not use where people will remain for more than a few minutes unless 
adequate shielding or other safety precautions are used.  The following designated Wobblelight

®

 metal halide lamps conform to federal regulations 21 

CFR 1040.30 (USA) and S0R/80-381 (Canada): 

Summary of Contents for Wobblelight 175-watt Metal Halide

Page 1: ...Click Here To View Item at www GapPower com...

Page 2: ...xtended period of time after Wobblelight unit has been turned off and can continue to cause burns x DO NOT attempt to remove the protective lens to change bulbs unless the Wobblelight unit is disconne...

Page 3: ...ube Metal halide arc tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as ballast failure or misapplication An a...

Page 4: ...8 minutes to achieve full brightness Metal halide lamps which are shut off and then turned back on while still hot may require 5 10 minutes to restart SAVE THESE INSTRUCTIONS Specific Precautions for...

Page 5: ...cap assembly by aligning the five mounting holes with the five mounting nuts note the dome handle should be aligned with the power switch 6 Re install the five mounting screws do not over tighten SAVE...

Page 6: ...2 Amps x To avoid possible electrical overload Wobblelight should only be plugged into 120 volt 60 Hz electrical service which is protected by a circuit breaker of 15 amps or less x DO NOT overload th...

Page 7: ...y outlet 9 Reset the circuit breaker and repeat steps 5 7 10 If the circuit breaker continues to trip and you are certain that the accessory outlet amp rating is not being exceeded or if nothing is co...

Page 8: ...ind to any products items or personal or other property caused by use of the Wobblelight product that is contrary to the instructions or documentation accompanying your Wobblelight product Costs of sh...