Quick start instructions
Figure 1.1
Hybrid Spot Control Panel
120
190
300
350
ELECTRODE
PRESSURE
CHARGING
BAT 1
BAT 1
ON
ON
ON
ON
BAT 2
BAT 3
BAT 4
PUSH TO
TEST BATTERY
WELD
WELD
TIME
POWER
SERVICE
BAT 1
TEST
READY
ON
OFF
BAT 2
TEST
BAT 3
TEST
BAT 4
TEST
HYBRID SPOT
CHARGING
BAT 2
CHARGING
BAT 3
CHARGING
BAT 4
DC AMPS
DC AMPS
DC AMPS
DC AMPS
260
0
40
80
12
0
160
Air Pressure
Air Cooling
Switch
Power
Switch
Weld
Switch
Weld
Time Knob
Battery
Selector
Switch
Charge
Indicator
Displays
System Display.
Shows battery voltage and charge current.
Air Pressure
Regulator
PHS-100
1.
Turn the power switch on the front panel ON (Fig 1.1).
2.
Connect Air to the air inlet located on the back panel.
5.
Place the welding gun at the weld area and press the lower trigger button to weld.
The upper weld button is for spreading the electrodes open for better access.
The welder is now ready to operate. Make sure air pressure is set at 90 PSI.
NOTE:
When the welder is not being used, turn the power switch off. Leave
power cord plugged in to allow unit to charge.
3.
Turn the “WELD SWITCH” to the weld position.
4.
Turn on the desired amount of battery power by using the battery selector
switches (1-4). For two-sided welding use 3 to 4 batteries in the ON position.
For single-sided welding use one battery. Adjust weld time to 260-300 for two-sided.
120 for single-sided.
Ready
Batt1
Batt2
Batt3
Batt4
15.30V
15.30V
15.30V
15.30V
1.5A
1.5A
1.5A
1.5A
4
Hybrid Spot