3 Installation
Air supply port
The Hybrid Spot welder must be connected to a pneumatic air network.
(100 PSI to 130 PSI)
1.
Connect the welder to the air supply via the threaded input port at
the rear of the welder using a standard connector.
2.
If not already set, adjust the air pressure setting on the welder front panel to
90 PSI (4-5 bar) (
refer to section 4.5 “Setting the pneumatic air pressure”
).
IMPORTANT!
The air must be clean and free from oil and
moisture. Use a filter.
Figure 3.2
Page 9
All Info Copyright © Pro Spot International Inc.
3.6 Connection of pneumatic air supply
3.5 Connection of electrical supply
IMPORTANT!
L'air doit être propre sans huile et
humidité. Utilisez un filtre.
Battery charging system:
The Hybrid Spot welder is equipped with an on-board charging system that
will charge all 4 batteries at once.
To activate charging, simply plug in the power cord to the outlet on the back
of the welder Fig 3.2 and the supply 120VAC or 240VAC for Europe, Australia,
and China. The power supply switches automatically between
120VAC and 240VAC.
It is possible to weld while the charging is activated; the charger will automatically
switch off when welding. The charger will turn back on 2 minutes after the last weld is
made. To check each battery’s voltage, turn the WELD switch to Bat 1 Test,
Bat 2 Test, etc.
To check the battery under load press “PUSH TO TEST BATTERY” button
for 3 seconds to see loaded voltage. Repeat for each battery.
11
Hybrid Spot