OPERATIONS
PRE-OPERATION CHECKS
WARNING! Do not start or run the generator in an enclosed
area, even if doors or windows are open. Engine exhaust
contains carbon monoxide, an odourless and colourless
poison gas.
Check the engine’s condition before operating to maximize the user’s
safety and the service life of the engine. Ensure that the generator is
level and the engine switch is in the OFF position before beginning the
pre-operation checks.
GENERAL CONDITION
1.
Look around and underneath the generator for signs of oil or
gasoline leaks.
2. Remove any excessive dirt or debris, especially around the muffler
and recoil starter.
3. Look for signs of damage.
4. Check that all shields and covers are in place.
5. Check that all nuts, bolts and screws are tight.
CHECK THE ENGINE
Consult the engine manual for additional details.
1.
Check the fuel level.
2. Check the engine oil level. Running the engine with a low oil level
can cause engine damage.
3. Check the air filter element. A dirty air filter will reduce engine
performance.
GROUND THE GENERATOR
The generator must be properly grounded to prevent electric shocks.
The generator is equipped with a ground terminal connector. Attach a
length of 10 AWG (minimum) wire to a ground rod driven into the earth.
Attached the other end to the ground terminal connector. Consult
V1.0
4,5000W GASOLINE INVERTER GENERATOR
8953176
Page 9
Assistance available at www.princessauto.com or 1-800-665-8685