60 Gallon Single Stage Stationary Air Compressor
14
For technical questions call 1-800-665-8685
8475006
V 1.6
Problem(s)
Possible Cause(s)
Suggested Solution(s)
Overheating.
1.
Poor ventilation.
2.
Dirty cooling surfaces.
3.
Restricted air passages.
1.
Relocate compressor to an area with
cool, dry, well circulated air, at least
12 in. (30.5 cm) from nearest wall.
2.
Clean all cooling surfaces thoroughly.
3.
Replace transfer tubes and/
or unloaded.
Excessive
belt wear.
1.
Pulley out of alignment.
2.
Improper belt tension.
3.
Pulley wobbles.
1.
Realign pulley with
compressor flywheel.
2.
Readjust.
3.
Replace the pulley and check for a
damaged crankshaft or flywheel.
Compressor
won’t start in
cold temperatures.
1.
Too much back pressure
in tank.
2.
40W oil in crankcase.
3.
Compressor too cold.
1.
Open drain valve when
starting motor.
2.
Use synthetic, non-detergent
air compressor oil suitable for
low temperatures.
3.
Move compressor to a
warmer location.