 Wiring

• To prevent an electric shock, prior to connecting the LogiTouch’s power

cord terminals to the power terminal block, be sure that the LogiTouch’s
power supply is turned OFF, via a breaker, or similar unit.

• The GLC150-BG41-RSFL-24V unit is designed to use only DC24V

input. Any other power level can damage both the LogiTouch and
the power supply.

• To prevent an electric shock or equipment damage, be sure to reattach

the plastic cover to the terminal block after completing any wiring.

WARNINGS

• To avoid a short caused by loose ring terminals, be sure to use

ring terminals with an insulating sleeve.

*1

• When the FG terminal is connected, be sure the wire is grounded. Not

grounding the LogiTouch unit will result in excess noise and vibration.

• Wherever possible, use thick wires (max. 2 mm

2

) for power terminals, and

twist the wire ends before attaching the ring terminals.

• Be sure to use the following size ring terminals.

„

„

„

„

„

Connecting the LogiTouch Power Cord

When connecting the power cord, be sure to follow the procedures given below.

1. Confirm that the LogiTouch’s Power Cord is unplugged from the power supply.
2. Use a screwdriver to remove the Power Input Terminal Block’s clear plastic cover.
3. Unscrew the screws from the middle three (3) terminals, align the Ring

Terminals and reattach the screws.

4. Confirm that the wires are connected correctly.
5. Replace the Power Input Terminal Block’s clear plastic cover.

Rear View

FG

+

Power Input

Terminal Block

under 6.0mm [0.24in]

over 

φφφφφ

3.2mm [0.13in]

The torque required to tighten these screws is 0.5 to 0.6Nm.

*1

Suggested Ring Terminal : V2-MS3 (made by JST)

FG

+

Summary of Contents for LogiTouch GLC150-BG41-RSFL-24V

Page 1: ...s load control power turning ON an incorrect output signal or malfunction could cause an accident to occur Be sure to design a program that will ensure the safety of your system in in the event of a...

Page 2: ...power cord is unplugged from the power supply Be sure to reattach the LogiTouch terminal block s plastic cover after completing any terminal wiring If this cover is not reattached an electric shock c...

Page 3: ...cident Be sure to secure all wiring terminal screws in place with the designated torque Screws and terminals that become loose can cause a short circuit fire or accident Be sure that metal filings or...

Page 4: ...st all be in accordance with Class I Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 or as speci fied in Section 18 152 of the Canadian Electrical Code for units inst...

Page 5: ...This Guide Option Items sold separately LogiTouch Series User Manual GLC150 MM01 Flex Network Cables Logic Program Developer Software LogiTouch Editor Data Transfer Cable GPW CB02 50m FN CABLE2050 31...

Page 6: ...cuit I Flex Network Connector J Flex Network LED Operation Mode 1 Controller Operation Mode 2 LED Color OFFLINE STOP Green Constant In Operation RUN Green Constant In Operation STOP Green Flashing In...

Page 7: ...will monitor the LT unit s circuits Contact Rating 0 15A AC125V Resistance Load 0 6A DC24V Resistance Load Operating Time Set Time at 20 o C 4ms or less Recover Time Reset Time at 20 o C 4ms or less...

Page 8: ...S 422 19 ERB Enable Receive B RS 422 20 ERB Enable Receive B RS 232C 21 CSA Clear Send A RS 422 22 ERA Enable Receive A RS 422 23 NC No Connection 24 NC No Connection 25 NC No Connection Recommended C...

Page 9: ...nformation about Flex Network or connectable Flex Network I O units see the Flex Network User Manual 5 Installation Before installing the LogiTouch into a cabinet or panel check that the installation...

Page 10: ...s show the four 4 fastener insertion slot locations Insert each fastener s hook into the slot and pull it back until the hook catches Insertion Slots Panel Hook Tightening the screws with too much for...

Page 11: ...unit will result in excess noise and vibration Wherever possible use thick wires max 2 mm2 for power terminals and twist the wire ends before attaching the ring terminals Be sure to use the following...

Page 12: ...ttaching a wire to the LogiTouch s rear face FG terminal on the Power Input Terminal Block be sure to create an exclusive ground 1 Inside the LogiTouch unit the SG Signal Ground and FG Frame Ground te...

Reviews: