Specifications

 General

Model Number

DR*-****BD

DR*-****FU

Rated Voltage

24VDC

100VAC to 240VAC

Allowable Voltage Range

19.2VDC to 30VDC

85VAC to 264VAC

Rated Frequency

-

50/60Hz

Allowable Frequency Range

-

47Hz to 63Hz

Allowable Voltage Drop

1ms or less

10ms or less

Power Consumption

DR2-*1*1BD                   3W
DR2-*201BD                  6W
DR3-B101BD                 3W
(When the I/O Extension
Module is connected)     8W
DR3-B261BD                 6W
(When the I/O Extension
Module is connected)    10W

DR2-*1*1FU                    7VA
DR2-*201FU                  11VA
DR3-B101FU                   7VA
(When the I/O Extension
Module is connected)     12VA
DR3-B261FU                  12VA
(When the I/O Extension
Module is connected)     17VA

Insulation Endurance

Insulation Resistance

In-Rush Current

Ambient Tempreture

Ambient Humidity

Atmoshperic Pressure

(Operating Altitude)

Pollution Level

1500VAC 5mA for 1 minute

(Between output terminals and DIN rail)

500VDC 100M

Ω

 or higher

(Between output terminals and DIN rail)

Level2

30A or less

0ºC to 55ºC

95%RH or less (No condensation)

Wet bulb temperature: 39ºC or less

800hPa to 1114hPa (At 2000m or less)

Summary of Contents for DR2-B121BD

Page 1: ...hese symbols and follow the instructions given Safety symbols and their meanings Safety Precautions DANGER A hazardous situation that will result in serious injury or even death if instructions are no...

Page 2: ...odule for special uses including nuclear power control devices electric power de vices aerospace equipment medical life support equipment or transportation vehicles please contact your local PRO iO2 d...

Page 3: ...wet cloth Doing so may cause a fire or an electric shock Be sure to install a fuse breaker etc in each of the power input and output circuits Failure to do so can lead to a fire if an overload occurs...

Page 4: ...dule 1 PRO iO2 Installation Guide English and Japanese This module has been carefully packed with special attention to quality How ever should you find anything damaged or missing please contact your...

Page 5: ...N CSA C22 2 No 142 M1987 c UL listed Electrical Control System for Industry Notes Note the following when applying for UL recognition for equipment in which the PRO iO2 module is installed The PRO iO2...

Page 6: ...anual PRO iO2 I O Extension Module Installation Guide 2 The figures in parentheses indicate the maximum number of input output points when the I O Extension Module is connected Model Number Voltage No...

Page 7: ...also function as a contact s open close button when creating modifying a logic programs 9 DIN Rail detachment hook Used when detaching the main module from a DIN rail 10 Relay output terminals Depend...

Page 8: ...are identical When attaching the PRO iO2 module to a panel extend the module s attach ment tabs When attaching the PRO iO2 module to a DIN rail retract the module s attachment tabs DR 1 DR 2 a 71 2mm...

Page 9: ...tension Module is connected 10W DR2 1 1FU 7VA DR2 201FU 11VA DR3 B101FU 7VA When the I O Extension Module is connected 12VA DR3 B261FU 12VA When the I O Extension Module is connected 17VA Insulation E...

Page 10: ...0VAC or less 0 05mA or less 50ms 50ms Input Signal Display via LCD Models DR B only Operating Voltage Input Delay I1 to IA IB to IG 7 4k At ON 12k At ON ON Voltage 15VDC or more 2 20mA or more 15VDC o...

Page 11: ...50VAC Output 4 Points DR 1 1 10 Points DR3 B261 Load Current No of Output Points 8 Points DR2 201 Common 1Only the DR3 B261 module s Q8 Q9 and QA share a single common terminal DR2 D201BD 2 IB IC DR B...

Page 12: ...e sure to also install a fan as shown in the right side figure The value in indicates measurements used for DR 2 PRO iO2 modules DIN Rail Installation Confirm that the DIN rail fastener hook is clippe...

Page 13: ...er ON CAUTION The following types of wires can be used 1 When operating devices with inductance loads such as magnets and valves Pro face recommends you use a diode surge killer or varistor DC Power M...

Page 14: ...is a fault in the power supply E g the AC line and the earth line are shorted the fuse connected to the L terminal will break and stop the flow of power WARNING 1 When operating devices with inductanc...

Page 15: ...ot use negative voltages for the analog inputs Doing so can damage the internal circuit The maximum length of the cable connected to an analog device is 10 m 1 1A Fuse Fast break type The following di...

Page 16: ...signates the password needed to access the logic program Press the Menu Ok button to enable the setting select a password using the Z1 to Z4 keys and press the Menu Ok button again to confirm the pass...

Page 17: ...or not This function is disabled in RUN mode TRANSFER Transfers a logic program to or from the memory pack PRO iO MEMORY From the PRO iO2 module to the memory pack MEMORY PRO iO From the memory pack...

Page 18: ...16 a contact b contact Timer C c C1 to CG c1 to cG 16 a contact b contact Counter K k 3 K1 k1 1 a contact b contact High Speed Counter V v V1 to V8 v1 to v8 8 a contact b contact Counter Comparator A...

Page 19: ...re cursor Moves the cursor and selects the type of instruction Returns to the menu screen Shift Button Functions Holding down the Shift button and then pressing the specified operation button allows t...

Page 20: ...button and press one of the Z1 to Z4 keys where you want to insert a branch A branch is created in the rung Deleting branches Use the Z keys to move the cursor to a branch area Hold down the Shift but...

Reviews: