40
The appliance must be connected to an operating, warrantied and cleaned
chimney in immediate proximity.
Convenience must be provided for servicing the WHS control components
–
fittings, manifolds, filters, expansion vessel, safety valve for overpressure up
to 2 atm, topping up and drainage valve group and automatic bleeding valves.
The appliance must be connected using union nut and valve fittings facilitating
disconnection for the cases of
preventive maintenance, without the need to
drain the water from the remaining part of the WHS.
Do not allow the heat
-
transfer agent to freeze in any part of the WHS, as this
can lead to explosion of the system.
Use water solution of Propylene glycol, in order to avoid any freezing, on the
one hand and on the other hand, congealing /blockage of the water pump as
a result from prolonged downtime.
Permanent and stabilized power supply from a Schuco power point with
overvoltage protection must be guaranteed.
The appliance must not be installed in a bedroom or children’s room.
Access for servicing must be provided.
4.1.
Fire safety clearances
There is no limitation for clearances from all sides for non
-
combustible
materials and they must only take into account the periodic maintenance
service, and the minimum clearance of the appliance from combustible
materials is 100 cm in front of it, 40 cm for the sides and 50 cm to the non
-
insulated flue stack along its whole length beyond the appliance body.
Where the flooring is combustible, use fire rated insulation mat, which must
extend 40 cm in front of the appliance and 20 cm for all other sides.
The connection of the appliance to the chimney must guarantee tightness,
security of fixing and prevention of any fire hazards.
4.2.
Connection to the chimney
The elements and facilities used for discharging the flue gases must be in conformity
with the existing standards.
The pipe diameter may not be smaller than the one of the flue gas fan. Before
connection, a revision of the smoke
-
discharge system must be performed by a specialist.
Flue stack made of metal pipes, must be insulated using non
-
combustible thermal
insulation and earth
-
bonded in accordance with the currently applicable legal provisions,
separately from the earth
-
bonding of the stove.
During installation, tightness of connection and structural stability must be
guaranteed.
Usage of shared chimney shall not be allowed. The chimney must be dedicated to the
stove and no other appliances, even ones that are not currently used may ever be
connected to it. In some multi
-
family residential buildings there may be collective
chimneys that are designed and constructed with special building structure, which is
intended to be used by more than one appliance. If this is the case, it must
be verified that
Summary of Contents for KPW 24
Page 3: ...3 5 3 14 21 5 3 15 22 5 4 23 6 26 6 1 26 6 2 27 6 3 27 7 29 8 29 9 31...
Page 4: ...4 1 1 1 1 1 1 1 4 1 1...
Page 5: ...5 1 2...
Page 6: ...6 1 3 2 1 1 2 230V50Hz 3 WiFi 4 40mm 5 1 6 4...
Page 9: ...9 10 3 1 EN14785 2006 EN 55014 EN 60335 EN 61000 EC 2015 1185 3 2 4...
Page 10: ...10 2 4 1 100 cm 40cm 50cm 40cm 20cm 4 2...
Page 11: ...11 3m 5 4 3...
Page 12: ...12 4 4 1 1 2 230V50Hz 3 WiFi 4 40mm 5 1 6 4 5 230V 50Hz...
Page 13: ...13 4 6 6mm 30mm 4 8 4 9 N plus 1 EN ISO 17225 2 2014 5 5 1...
Page 14: ...14 30 5 2 250W 1 5 30 Start Stop...
Page 15: ...15 5 3 Fumis Premium 3 1 3 6 3 Start Stop 3...
Page 16: ...16 Fumis Premium USB 5 3 1 23 5 18 0 5 3 2 5 3 3...
Page 17: ...17 5 3 4 NO I03 GND WiFi 5 3 5 A1 6 35 40 1 5 3 6...
Page 19: ...19 5 3 8 3 20 C 4 C 5 3 9 30 30...
Page 20: ...20 5 3 10 OFF LOW HI LOW OFF LOW HI 5 3 11 50 80 2 51...
Page 22: ...22 2 2 55 55 5 3 15 OFF 4 8 FIREUP...
Page 24: ...24 A002 A003 A004 A005 E001 E101 E102 1 2 3 4 E105...
Page 25: ...25 E106 E108 E109 E110 E111 E113 E114 E115 1 1 2 https prity bg com...
Page 26: ...26 6 6 1 4 4 5 5...
Page 27: ...27 6 2 1 2 6 3 5 6...
Page 28: ...28 2 4 6 7 https prity bg com...
Page 29: ...29 7 http prity bg com service 359 878 881 354 8 36 3600 1500...
Page 30: ...30 01 02 2022...
Page 31: ...31 9 112 115 112 115 95 33 www prity bg com...
Page 61: ......
Page 62: ......
Page 63: ......