background image

Производител: "Прити 95" ООД , България,  гр.Лясковец  ул."Максим Райкович" 

33

 

Manufacturer

: "Prity 95" OOD, Bulgaria, Lyaskovets Maksim Raykovich Street No. 33 

www.prity

-

bg.com 

МОДЕЛИ /MODELS/: 

PLW11; PLW18; PLW25; PLW35; 

KPW11; KPW24; PLW18B; 

PLW25B; PLW35B

 

 

 

 

стр.

2

 

РЪКОВОДСТВО 

ЗА ИНСТАЛИРАНЕ И УПОТРЕБА НА ПЕЛЕТНИ ОТОПЛИТЕЛНИ 

УРЕДИ 

"ПРИТИ" 

С ВОДЕН ТОПЛООБМЕННИК 

p.3

2

 

INSTALLATION AND OPERATION 

MANUAL

 

FOR PELLET BURNING HEATING APPLIANCES 

"PRITY" 

WITH 

WATER HEAT EXCHANGER 

 

 

 

 

 

 

   

 

 

 

Summary of Contents for KPW 24

Page 1: ...aria Lyaskovets Maksim Raykovich Street No 33 www prity bg com MODELS PLW11 PLW18 PLW25 PLW35 KPW11 KPW24 PLW18B PLW25B PLW35B 2 p 32 INSTALLATION AND OPERATION MANUAL FOR PELLET BURNING HEATING APPLI...

Page 2: ...3 1 9 3 2 9 4 9 4 1 10 4 2 10 4 3 11 4 4 12 4 5 12 4 6 13 5 13 5 1 13 5 2 14 5 3 Fumis Premium 15 5 3 1 16 5 3 2 16 5 3 3 16 5 3 4 17 5 3 5 17 5 3 6 17 5 3 7 18 5 3 8 19 5 3 9 19 5 3 10 20 5 3 11 20...

Page 3: ...3 5 3 14 21 5 3 15 22 5 4 23 6 26 6 1 26 6 2 27 6 3 27 7 29 8 29 9 31...

Page 4: ...4 1 1 1 1 1 1 1 4 1 1...

Page 5: ...5 1 2...

Page 6: ...6 1 3 2 1 1 2 230V50Hz 3 WiFi 4 40mm 5 1 6 4...

Page 7: ...m3 3 kW 6 kW 8 kW 4 kW 8 kW 6 kW 8 kW 12kW 112 C 101 C 115 C 112 C 115 C 101 C 115 C 115 C 92 92 92 92 2 92 92 2 92 92 O2ref 13 0 0060 0 0123 0 0158 0 0077 0 0090 0 0194 0 01079 0 01079 21 l 22 l 28 l...

Page 8: ...213 kg 560 mm 560mm 560 mm 490 mm 550 mm 560 mm 560 mm 580 mm 560 mm 550mm 600 mm 620 mm 690 mm 550 mm 600 mm 630 mm 880 mm 965mm 990 mm 1190 mm 1340 mm 965 mm 990 mm 1160 mm 40mm 80mm 100mm 100mm 80m...

Page 9: ...9 10 3 1 EN14785 2006 EN 55014 EN 60335 EN 61000 EC 2015 1185 3 2 4...

Page 10: ...10 2 4 1 100 cm 40cm 50cm 40cm 20cm 4 2...

Page 11: ...11 3m 5 4 3...

Page 12: ...12 4 4 1 1 2 230V50Hz 3 WiFi 4 40mm 5 1 6 4 5 230V 50Hz...

Page 13: ...13 4 6 6mm 30mm 4 8 4 9 N plus 1 EN ISO 17225 2 2014 5 5 1...

Page 14: ...14 30 5 2 250W 1 5 30 Start Stop...

Page 15: ...15 5 3 Fumis Premium 3 1 3 6 3 Start Stop 3...

Page 16: ...16 Fumis Premium USB 5 3 1 23 5 18 0 5 3 2 5 3 3...

Page 17: ...17 5 3 4 NO I03 GND WiFi 5 3 5 A1 6 35 40 1 5 3 6...

Page 18: ...6 16 C T1 20 C T5 22 C 6 16 C T2 21 C T5 22 C 6 16 C T2 21 C T5 22 C 6 16 C T1 20 C T4 23 C 6 16 C T1 20 C T4 23 C 6 16 C T2 21 C T4 23 C 6 16 C T1 20 C T3 20 5 C T1 07 00 11 00 20 C T2 07 00 17 00 21...

Page 19: ...19 5 3 8 3 20 C 4 C 5 3 9 30 30...

Page 20: ...20 5 3 10 OFF LOW HI LOW OFF LOW HI 5 3 11 50 80 2 51...

Page 21: ...21 5 3 12 WiFi Wireless FumisWiRCU iOS Android http www fumis si en wircu connection guide 5 3 13 Wi Fi WiFi https prity bg com 5 3 14 Fumis Alpha 75V2 EEPROM Fumis ALPHA...

Page 22: ...22 2 2 55 55 5 3 15 OFF 4 8 FIREUP...

Page 23: ...23 5 4 Low battery Low battery call service for its replacement Fire error Error probable causes 1 Ignition failed 2 Water overtemperature 3 Backfire protection BURNING 1 5 FIREDOWN...

Page 24: ...24 A002 A003 A004 A005 E001 E101 E102 1 2 3 4 E105...

Page 25: ...25 E106 E108 E109 E110 E111 E113 E114 E115 1 1 2 https prity bg com...

Page 26: ...26 6 6 1 4 4 5 5...

Page 27: ...27 6 2 1 2 6 3 5 6...

Page 28: ...28 2 4 6 7 https prity bg com...

Page 29: ...29 7 http prity bg com service 359 878 881 354 8 36 3600 1500...

Page 30: ...30 01 02 2022...

Page 31: ...31 9 112 115 112 115 95 33 www prity bg com...

Page 32: ...ains 42 4 6 Pellets used 42 5 STOVE OPERATION 43 5 1 Preparation for initial ignition 43 5 2 Ignition fire up and shutting down the stove 43 5 3 Description of the control panel with Fumis Premium dis...

Page 33: ...nal battery 50 5 3 15 Work phases and sequence of processes 51 5 4 Warnings and alarms 52 6 CLEANING AND MAINTENANCE 55 6 1 Daily cleaning 55 6 2 Periodic cleaning 56 6 3 Seasonal cleaning and prevent...

Page 34: ...utomatic mode of fuel supply which is the reason when choosing the model not to resort to higher capacity stove to cover potential heat losses due to dying down combustion process Sometimes during the...

Page 35: ...ns required through the rpm control of the flue gas fan The software has been specifically designed and set up for every particular model and operation mode aiming at minimizing the number of kindling...

Page 36: ...Back view diagram 1 Hot water outlet stub pipe 1 2 Power supply 230V 50Hz 3 WiFi switch 4 Combustion air inlet 40mm 5 Cold water inlet stub pipe 1 6 Flue gas outlet to the chimney Parts of the produc...

Page 37: ...8 kW 12kW Flue gas temperature up to 112 C 101 C 115 C 112 C 115 C 101 C 115 C 115 C Efficiency up to 92 92 92 92 2 92 92 2 92 92 CO emissions for rated power O2ref 13 0 0060 0 0123 0 0158 0 0077 0 0...

Page 38: ...mplexity of this appliance handling it requires certain minimum of knowledge and skills acquired corresponding to a successfully completed secondary school education All instructions provided by the m...

Page 39: ...hall bear no liability in cases of damage or accident caused by the following circumstances in the process of operation Failure to comply with the instructions Failure to comply with the usual rules f...

Page 40: ...e from combustible materials is 100 cm in front of it 40 cm for the sides and 50 cm to the non insulated flue stack along its whole length beyond the appliance body Where the flooring is combustible u...

Page 41: ...stion process To ensure normal combustion process and clean surrounding atmosphere sufficient amount of air must be supplied If the room has tightly fitted doors and windows it is necessary to provide...

Page 42: ...bined device for stabilization of voltage to a normal sinusoidal waveform and its redundancy using deep cycle battery is recommended Usage of devices with pulsed non sinusoidal voltage is absolutely f...

Page 43: ...play and perform any adjustments if necessary Verify the indication of the clock and the calendar Carefully fill the hopper observing for any objects or materials which are not pellets Before switchin...

Page 44: ...perature control from an external thermostat may also be set up and to this end this option must be enabled from the user menu In operation mode the appliance will constantly strive to achieve the pre...

Page 45: ...tching on off and the desired temperature are to be pre set Statistics the statistics menu provides information about events in past periods Settings main menu allowing settings of time date fuel exte...

Page 46: ...hanging the language the display will restart automatically This may take several minutes 5 3 4 Setting External thermostat Settings External thermostat Option for inclusion of an external room thermo...

Page 47: ...e Air second medium temperature External thermostat and water temperature Water and you can switch between these types by just touching them 5 3 7 Setting up of weekly programs Timers day time 0 1 2 3...

Page 48: ...s IMPORTANT Where the current temperature is already higher than the pre set temperature within a time interval which should appear the heating device will not switch on automatically until the actual...

Page 49: ...locking of the screen you can move around within the menu and show the current values but you cannot edit any the settings except for the screen locking itself OFF screen locking is disabled all funct...

Page 50: ...umis si en wircu connection guide 5 3 13 Remote stove switch on off via Wi Fi This function gives you the option for starting and shutting down the stove from your smartphone using a WiFi controlled r...

Page 51: ...vice will restart If their temperature is at least 55 the operation continues in Burning mode 5 3 15 Work phases and sequence of processes Work phase Work sequence Functions OFF SWITCHED OFF Switched...

Page 52: ...g screen touch it Closure of the warnings screen does not reset the warning After the warning screen is closed the warning code is still present in the top left corner of the main screen as well as on...

Page 53: ...leaning of the heat exchanging pipes inspection openings flue gas fan stove pipes and chimney is required A004 Depleted battery Depleted battery Contact the service station for replacement A005 Fan sp...

Page 54: ...nge rate Clean the firebox from any cinder the heat exchanging pipes the inspection openings and turbolators E114 No fuel Inspect for presence of pellets and for normal operation of the delivery auger...

Page 55: ...deposits The firepot should be very carefully and accurately replaced back to its holding box until well seated Incorrect placement results in excess combustion air passing around it seriously deterio...

Page 56: ...3 Seasonal cleaning and preventive maintenance Apart from the operations part of the daily and periodic cleaning before the new heating season a complete and thorough cleaning and preventive maintenan...

Page 57: ...he service technician must inspect the flue gas fan the seals and operation settings of the controller All activities related to the daily periodic and seasonal preventive maintenance are to the best...

Page 58: ...f this device is 36 thirty six months from the date of sale or 3600 working hours whichever is first The warranty period of the igniter is one year or 1500 cycles After replacing of an actuating mecha...

Page 59: ...ure natural disasters and others beyond the manufacturer s control There are defects as a result from clogged chimney not cleaned flue gas pipes heat exchanger channels firebox smoke chamber fan or in...

Page 60: ...ty shall only be valid if this warranty card was filled in and signed in a legible manner in ink or by pen and stamped a sale in accordance with the warranty under art 112 115 of the Consumer Protecti...

Page 61: ......

Page 62: ......

Page 63: ......

Page 64: ...d Warranty for connection to the chimney Name Tel Signature Warranty for Schuco type electricity supply system Name Tel Signature Warranty for water heating system Name Tel Signature Customized softwa...

Reviews: