62
Date:
20-11-2014
Data name:
esc300-2-v12a_EN
ESC300 (swv-1.06)
Author:
Heiko Lange
Pages:
72
© P. Prinzing GmbH - 89173 Lonsee-Urspring (Germany)
Service: +49 (0) 7336 - 961018
* Option / depends on design
Factory provided parameters
Parameter
Option/area
Now
• Main settings
Language
GER
ENG,FRE, RUS
Date
current
set
Time
current
set
Alley selection
1 (On)
2...6 (On/Off)
• Frost mode (sub menu)
Switch on temp.
0°C
-25°C...50°C
Interval time
60 min
1...90 min
Interval time
10 min
1...90 min
Delay (frost)
10 min
5...30 min
• Obstacle (sub menu)
Time reverse
10 sec
0...60 sec
Number trials
3
0...99
• Service (sub menu)
Signal drive
Off
On, error, cross
transport
Lightness LCD
100 %
0...100 %
Tension control
15
0...99
9.
Factory provided parameters
Parameter
Option/area
Now
• Menu alley (1...6)
Automatic
Off
On
• Setup (sub menu)
Motor type forward
0,55
kW
0,75 - 0,9 - 1,1 - 1,5
Motor type backward
0,55
kW
0,75 - 0,9 - 1,1 - 1,5
Switch off forward
80 %
1...115
Switch off backward
80 %
1...115
• Schedule (sub menu)
Time
00:00
00:01...24:00 (24x)
Program
P1
P2 - P3 - P4
• Drive (sub menu)
Drive
Off
On
Driving time
15
0...6000
Slatted fl oor
Off
On
• Frost mode (sub menu)
Frost mode
Off
On
Frost program-type
P1
P2 - P3 - P4
• Program 2 (sub menu)
Time till cycling
0
learning or manual
Cycle length
15 sec
0...6000
Pause duration
5
0...6000
Number cycles
3
0...99
Parking position
0
0...6000
• Program 3 (sub menu)
Adaption forward
0,0
-9,9...+9,9
Adaption backward
0,0
-9,9...+9,9
• Cross transport
Cross transport forw.
Off
On
Cross transport back.
Off
On
Duration cross
transport
1