Error
Cause
Deletion
Scraper/control is not or bad reacting
on keystroke on the remote
radio contact is bad or interrupted
- lower distance between remote <>
radio module
- check assembling of the radio
module (see
page 11
)
- install an additional radio module
Set or changed parameters can not
be saved
settings were not saved by the
ENTER
button
after setting/changing values always
save with
ENTER
Date and time are reset
control was switched off for a longer
time (> 48 h)
readjust date and time
The
status indication alley
displays of
all alleys an ?
mains voltage was interrupted,
current dataset is lost
after a complete scraper drive the posi-
tions will be displayed again
Parameter-dataset not load
When starting, it was not possible to
load one of the two parameter-dataset
out of the EEProm.
switch off/on the system
8.7.5 Further errors
Error
Cause
Deletion
Control is not booting completely after
starting. Display is glowing but not
message on the display.
Defective SD-memory card
- extract the SD-card, reformat (FAT
FAT32) or use new SD-card
- use new SD-card (max. 2GB)
Not possible to save data on the
SD-card
wrong or faulty SD-card,
write protection of the SD-card active
- extract SD-card and reformat (FAT/
FAT32)
- use new SD-card (max. 2 GB)
- deactivate write protection