42
www.pridemobility.com
Jazzy 1113 ATS
V I I . O P E R A T I O N
Actuator Lighting Module (Not Shown)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power
interface between the power module, the lights, and/or the power seat actuator.
Sleep Mode
Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off the main
power if the joystick is not moved in any direction for approximately five minutes. The battery condition meter lights on the
keypad indicate sleep mode by blinking once every five seconds. To restore power and continue, push the on/off key twice.
Thermal Rollback
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors, power module,
and remote. In the event that any of them become excessively hot (above 122° F), motor voltage is reduced. For every degree
above 122° F, the voltage is reduced by 5 volts. This reduces your power chair’s speed and allows the electrical components to
cool down. When the temperature returns to a safe level, your power chair resumes its normal speed.
Remote Plus Error Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems
with your power chair’s electrical system. If any of the battery condition meter lights are flashing rapidly, the controller may
be indicating an error. Error codes are displayed as a number of flashing lights. For instance, if the first light is flashing
rapidly, the battery voltage is nearly depleted. The table below identifies the individual error codes, probable causes, and
possible solutions. If you get one of these error codes, contact your authorized Pride Provider.
FLASHING LIGHTS
DIAGNOSIS
SOLUTION
10
High Battery Voltage
Check batteries.
9
Solenoid Brake Fault
Check motor/brake wiring.
8
Possible Controller Fault
See authorized Pride Provider.
7
Possible Joystick Fault
See authorized Pride Provider.
6
Inhibit Active
Unplug charger. Check connections.
5
Right Motor Wiring Fault
Check right motor wiring.
4
Right Motor Disconnected
Check right motor wiring.
3
Left Motor Wiring Fault
Check left motor wiring.
2
Left Motor Disconnected
Check left motor wiring.
1
Low Battery Voltage
Check batteries/battery wiring.