background image

APS25Z_RevA_08/18

7

 Detailed Descriptions: 

Setup Options

Security Control (Bank 2) (cont.)

 

See page 8 for Programming Instruction.

 Feature 6: 

Park Light / Trunk Relay Function

Function: 

Reverse the functionality of the trunk and park light outputs (i.e. when the built-in relay is needed for the 

trunk connection but not needed for the park light connection.)

Setting Choices:

•  Option 1 -

 Functionality follows 

default settings

.

•  Option 2 -

 The 

Trunk Release Output (Dark Blue)

 wire works with the Parking Lights function; the 

Parking 

Lights Input (White/Red) 

and 

Parking Lights Output (White)

 wires work with the trunk release function.  

 Feature 8: 

Exterior Illumination

Function: 

Set the parking lights to remain on for 30 seconds when the doors are locked or unlocked with the remote 

control. 

Setting Choices:

•  Option 1 -

 The lights will function 

normally.

•  Option 2 -

 The lights will remain on for 

30 seconds when the doors are locked 

with the remote control. 

•  Option 3 -

 The lights will remain on for 

30 seconds when the doors are unlocked

 with the remote control. 

•  Option 4 -

 The lights will remain on for 

30 seconds when the doors are locked or unlocked

 with the remote 

control.

 

Feature 7: 

Silent Choice

TM

Function: 

Set audible beeps on or off when arming and disarming the system. 

Setting Choices:

•  Option 1 -

 

Pressing Lock or Unlock at any time

 will perform the function 

with audible beeps.

•  Option 2 - Pressing Lock or Unlock for 1.5sec

 on remote will control system 

without an audible beep.

•  Option 3 - First press

 of Lock or Unlock on the remote control will perform the function 

without an audible 

beep

Second press within 10sec will result in audible beeps

.

 Feature 5: 

Automatic Arming

Function: 

Set the system to arm automatically after exiting the vehicle. 

Setting Choices:

•  Option 1 - 

System will 

arm and doors will lock only when the alarm is armed from the remote control. 

 

•  Option 2 - 

System will 

arm automatically 1 minute after the last door is closed

, and when the alarm is 

armed from the remote control.

•  Option 3

 - System will 

arm and lock doors automatically 1 minute after the last door is closed

, and when 

the alarm is armed from the remote control.

Summary of Contents for APS25Z

Page 1: ...ge products If you are a consumer please note Professional installation is strongly recommended This manual assumes the installer has adequate knowledge of the following expertise Therefore it does not cover these topics in detail 12 volt electronics Testing and verifying circuits Making safe and lasting wiring connections Factory ignition power lighting data bus and sensing systems Factory system...

Page 2: ...t wire based on the connection of the relay input WHITE RED wire Verification The vehicle parking light wire registers 12 Volt or Ground when the park lights are turned on Note This wire can be programmed to perform the Trunk Release Output function by changing its options Refer to Bank 2 Feature 6 on page 8 2 WHITE RED Parking Light Relay Input Internal Relay Pin 87 The WHITE RED connects to vehi...

Page 3: ...connects to the vehicle s primary ignition wire This wire will be used for system programming and override Verification This ignition wire registers 12 Volt when the key is in the accessory ignition and start positions Note Before making this connection remove all module fuses until the system is completely connected Main Input Output Connector 11 pin connector See page 15 for the full system diag...

Page 4: ... hole and mount the LED Valet button Route the wires to module and plug into proper location Three Button Remotes 1 Way Bu on Ac on Func on Press 1x Lock Hold 3 Seconds Panic ON OFF Press 1x Unlock Hold 3 Seconds Panic ON OFF Press 2x No Func on Hold 3 Seconds Trunk Release Remote Control Operation This system includes two 2 1 Way three 3 button remotes The matrix below describes the basic functio...

Page 5: ...l Deleting All Remotes 1 Perform steps 1 3 above 2 Press and Hold the Valet Override Button for five 5 seconds 3 The system will sound one 1 long beep This indicates all remotes have been deleted from memory Notes The system will store in the memory a maximum of four 4 remote controls Additional programmed remote controls will delete the oldest programmed remote control The system will accept a ma...

Page 6: ... output will pulse twice 500ms each Unlock output will pulse for 500ms Option 5 Lock and Unlock outputs will pulse twice for 500ms Option 6 Lock output will pulse for 500ms Unlock output will pulse for 350ms Feature 2 Accessory Activated Lock Function Set the door locks to lock after the ignition is turned ON Setting Choices Option 1 Doors do not lock with ignition on Option 2 Doors Lock with igni...

Page 7: ... remain on for 30 seconds when the doors are unlocked with the remote control Option 4 The lights will remain on for 30 seconds when the doors are locked or unlocked with the remote control Feature 7 Silent ChoiceTM Function Set audible beeps on or off when arming and disarming the system Setting Choices Option 1 Pressing Lock or Unlock at any time will perform the function with audible beeps Opti...

Page 8: ...xit Procedure 1 Turn the ignition ON 2 Press and release the valet override button 3x 3 The system will beep 1 one time indicating you have accessed Bank 1 4 Each cycle of the Ignition OFF ON will advance to the next bank up to Bank 3 then restart at Bank 2 Note To re access Bank 1 for transmitter programming you will need to exit and re enter programming mode 5 The system will beep a number of ti...

Page 9: ...ptions Features 1 Auto Program Lock 2 Unlock 3 Trunk Start Feature Bank 1 Description CH Press Lock button on remote Press Unlock button on remote Press Start button on remote Dome Light Delay To program the Prestige system to wait until the dome light turns off before arming 1 Close all doors 2 With the vehicle ignition off press LOCK UNLOCK LOCK UNLOCK LOCK UNLOCK LOCK on the remote control The ...

Page 10: ...ing the programming feature banks 1 Turn the ignition ON OFF ON OFF 2 Press and hold valet button for five 5 seconds The system will respond with one 1 beep for ON or two 2 beeps for OFF Adjusting the Shock Sensor 1 Arm the system wait 5 10 seconds then with an open palm carefully apply impact to areas of the vehicle to test the shock sensor s sensitivity 2 To adjust turn the adjustment knob on th...

Page 11: ...e activated Negative Trigger Door Locks Verification The vehicle wires register Ground when the Lock and Unlock switches are activated Lock Unlock Vehicle Door Lock Control Relays RED Lock Output GREEN Unlock Output Lock Unlock 87 87a 86 85 30 87 87a 86 85 30 Vehicle Door Lock Control Relays Fused 12 Volt Battery Souce Fused 12 Volt Battery Souce RED Lock Output GREEN Unlock Output ...

Page 12: ...sitive Multiplex Door Locks Relays required Verification The vehicle wire registers variable 12V values when the Lock and Unlock switches are activated Please consult the vehicle specific wire and location chart for resistor values Lock Unlock Vehicle Door Lock Control Relays RED Lock Output Green Unlock Output 87 87a 86 30 87 87a 86 30 85 85 Fused 12 Volt Battery Source Ground Resistor Lock Unloc...

Page 13: ...ed Aftermarket Actuators Relays and door lock actuators required Lock Unlock 87 87a 86 85 30 87 87a 86 85 30 Fused 12 Volt Battery Souce Fused 12 Volt Battery Souce RED Lock Output Green Unlock Output X Cut X Cut To Door Lock Motor To Door Lock Motor 30 87 87a 86 85 Fused 12 Volt Batter y Source Door Lock Actuator 30 87 87a 86 85 Chassis Ground Chassis Ground RED Lock Output GREEN Unlock Output Fu...

Page 14: ...k Reference Wiring Diagrams Starter Kill Anti Grind Relay Connections Included Starter Kill Anti Grind Relay L O C K A CC ON S T A R T CUT 87 87a 86 85 30 To Vehicle Ignition To ORANGE Starter Kill Anti Grind Output From Alarm ...

Page 15: ...Main 2 Green Unlock Output 1 Red Lock Output Door Lock 2 Red Battery 12V 1 Blue LED Output LED 2 Gray Valey Switch Input 1 Black Ground Output Valet 4 Red Battery 12V 3 Black Data TX 2 Green Warn Away Input 1 Blue Full Trigger Input Shock Replacement Part 4120468 Replacement Part 4120469 Replacement Part 4120474 Replacement Part 4700033 Replacement Part 4360842 1 2 86 85 87 87A 30 85 Red Ignition ...

Reviews: