24
Function Description
Remote Status
The J8 RS-232 port is normally used for the Servo Control 9600 baud 8N1 xon/xoff. The “Press Utility” REMOTE
menu is by default set to “RMT OFF”.
When the “Press Utility” REMOTE menu is set to “RMT ON”, the J8 RS-232 serial port is enabled for 57600 baud
8N1 xon/xoff Remote Status Commands (see table below). (see page 21 Remote Status section).
When the “Press Utility” REMOTE menu is set to “TCP ON”, the J8 RS-232 serial port needs to be connected to
the Optional Ethernet board. This 6.5” x 5.0” board contains an Ethernet Jack with built in Web server. The CD
that came with the Presscam 8 contains an Ethernet folder with the documentation on
fi
nding the IP address of
the Ethernet device and how to attach and run the board.
Command
Function
Return Size
Return Format
String to PCS
$A:
Job #
Byte (0 to 255)
@ job # &
$C:
Press Angle
Word (0 to 359)
@ angle &
$D:
SPM
Word (0 to 999)
@ SPM &
$E:
Die Fault
Byte (bit: 0=ok, 1=fault)
@ die &
$F:
PLS Status
Byte (bit: 0=off, 1=on)
@ PLS &
$G:
Status
Byte (see table)
@ status &
$H:
Fault codes1
Word (see Appendix A, each bit
@ fault1 &
represents a fault code)
$I:
Fault codes2
Word (see Appendix A, each bit
@ fault2 &
represents a fault code)
$J:
Fault codes3
Word (see Appendix A, each
@ fault3 &
bit represents a fault code)
$K:
StopTime
Word (0 to 999 msec)
@ stoptime &
$L:
Runtime meter
Long (in seconds)
@ runtime &
$M:
Strokes
Long
@ strokes &
$N:
Parts
Long
@ parts &
$O:
Batches
Long
@ batches &
$P:
Tonnage CH 1
Word
@ tonnch1 &
$Q:
Tonnage CH 2
Word
@ tonnch2 &
$R:
Tonnage CH 3
Word
@ tonnch3 &
$S:
Tonnage CH 4
Word
@ tonnch4 &
$T:
Opto Input status
Long (Each bit corresponding
@ input &
to each input)
=
Command String not completed within time allowed, reset command.
$
ASCII character sent to PressCommander to initiate command sequence
:
ASCII character sent to PressCommander to complete command sequence
$
ASCII character sent from PressCommander to indicate valid initiate
!
ASCII character sent from PressCommander to indicate command number received
@
ASCII character sent from PressCommander to indicate valid command number
?
ASCII character sent from PressCommander to indicate invalid command number
&
ASCII character sent from PressCommander to indicate end of transmission
Word
2 Bytes
Long
4 Bytes
PressCam 8 J8: RS-232 Remote Status Commands
Summary of Contents for PressCam 8
Page 1: ...PressCam 8 Installation Operations Manual ...
Page 2: ...Rev 5 0 ...
Page 14: ...6 Internal Wiring Diagram 28 101 System Installation ...
Page 15: ...7 Control Box Dimensions 28 102 System Installation ...
Page 16: ...8 Panel Cut Out Dimensions 28 103 System Installation ...
Page 17: ...9 Control Panel Dimensions 28 104 System Installation ...
Page 18: ...10 System Installation External Wiring Diagram 28 105 ...
Page 19: ...11 System Installation I O Board Dimensions 28 106 ...
Page 44: ...36 Tonnage Load Monitor optional Installation T400 Installation ...