Set Points
STROKE COUNT:
0 to 999,999 strokes
BATCH COUNT:
0 to 999,999 strokes
QUALITY COUNT:
0 to 999,999 parts
PART COUNT:
0 to 4
parts/stroke
0 to 999,999 parts total
BATCH SIZE:
0 to 999,999 strokes
Limit switch angle:
0 to 359
degrees
Limit switch timer:
0 to 9999
milliseconds
Die sensor angle:
0 to 359
degrees
Speed Compensation: 0 to 99
degrees
MIN SPEED:
0 to 999
SPM
MAX SPEED:
0 to 999
SPM
Brake WARNING:
1 to 999
milliseconds
Brake FAILURE:
1 to 999
milliseconds
Brake ACTUAL:
1 to 999
milliseconds
(+/-1 millisecond
accuracy)
MOTION:
0 to 5.9
seconds (1/10-
sec increments)
DRIFT:
preset to 2 SPM (1/10 SPM
increments)
Crank Angle:
0 to 359
degrees (1°
increments)
SPM:
0 to 999
strokes/minute
(+/- 1 SPM
accuracy)
Resolver
+/- 1º Resolution up to 600 RPM (+/- 2º
Resolution from 601 to 1000 RPM)
Shaft loading: Radial 400 lbs., Axial 200 lbs.
Standard cable 30’ (maximum length of 600’)
Construction
Stand
Alone
Unit
All 18 Gauge painted steel NEMA 12
lockable box with sealed front panel (see
dimensional information in
System Installation
section).
Panel Mount Unit
All 18 Gauge painted steel NEMA 12
lockable box with sealed front panel (see
dimensional information in
System Installation
section).
Temp. Range
0 to 50ºC
Dimensions
See “System Installation” section.
Introduction
Summary of Contents for PressCam 8
Page 1: ...PressCam 8 Installation Operations Manual ...
Page 2: ...Rev 5 0 ...
Page 14: ...6 Internal Wiring Diagram 28 101 System Installation ...
Page 15: ...7 Control Box Dimensions 28 102 System Installation ...
Page 16: ...8 Panel Cut Out Dimensions 28 103 System Installation ...
Page 17: ...9 Control Panel Dimensions 28 104 System Installation ...
Page 18: ...10 System Installation External Wiring Diagram 28 105 ...
Page 19: ...11 System Installation I O Board Dimensions 28 106 ...
Page 44: ...36 Tonnage Load Monitor optional Installation T400 Installation ...