30
MEM
Memory function (input data, recall or delete) activated
VOX
VOX function activated
Function key activated (selection of the frequency bands)
Shows the channel number
Shows the selected configuration
4) CHANNEL SELECTOR:
s
and
t
keys on front panel and
«UP» and «DN» on the microphone ~ SCAN
CHANNEL SELECTOR
(short press)
These keys allow to change the channel (up/down). A beep sounds
each time you change the channel if the
KEY
BEEP
function is activated
(
see §
KEY BEEP
page 32
)
SCAN
(very long press)
Channel Scan
Press and hold down one of the
s
/
t
key on the front panel or
UP
or
DN
on the microphone (
4
) for ± 5 seconds, or until a beep sounds
(see §
KEY BEEP
page 32)
, to activate the
SCAN
function.
«SCAN»
is
displayed. The scanning stops as soon as there is a busy channel. The
scanning starts automatically 3 seconds after the transmission stops
and no key is pressed during 3 seconds. The scanning restarts also
in upward direction with the
s
key on the front panel or
UP
on the
microphone, or in a downward direction with the
t
key of the font
panel or
DN
on the microphone.
Memory Scan
a)
Short press
MEM
(
5
)
during the
channel
scanning.
«MEM»
is displayed.
The transceiver scans the memories (
M1
,
M2
,
M3
) and channel
9
and
19
.
b)
Short press
MEM
(
5
) again during
memory
scanning
to go back to
channel
scan.
“SCAN”
is displayed,
“MEM”
disappears.
Press
PTT
(
11
) switch or
EMG
(
6
) key to exit the
SCAN
function.
“SCAN”
disappears on the display.
5) F - FREQUENCY BAND SELECTION ~ MEM
F - FREQUENCY BAND SELECTION
See § page 32
.
MEM
3 channels can be memorized with following parameters: AM (except
for
EC
configuration) or FM; LOCAL; NB/ANL; HICUT (and CEPT/ENG in
the
U
configuration)
To memorize
:
-
Long press on
MEM
(
5
),
«MEM»
blinks.
-
Press during 1 s on
M1
(
8
),
M2
(
7
) or
M3
(
6
).
«MEM»
is displayed contin-
uously. The channel has been memorized.
To recall a memory:
-
Long press on
MEM
(
5
),
«MEM»
blinks.
-
Short press on
M1
(
8
),
M2
(
7
) or
M3
(
6
).
-
«MEM»
is displayed continuously. The memorized channel is active.
To delete a memory:
-
Turn off the transceiver.
-
Keep key
M1
,
M2
or
M3
pressed and switch on the transceiver.
-
The selected memory is deleted.
6) EMG ~ DW ~ M3
EMG
(short press)
Channel
9
and
19
are automatically selected by pressing this key. A
first press activates channel
9
. A second press activates channel
19
.
«EMG»
appears on the display when a priority channel is active. A new
press returns to the previous channel and
«EMG»
disappears.
DW
(long press)
A longer press (1s) allows to activate the
Dual Watch
function. This
function allows to survey between channel 9 or 19 and the selected
channel. A first long press activates the
DW
function between channel
9
and the busy channel. A new long press activates the function between
channel
19
and the busy channel.
«DW»
is displayed. The number of
the selected channel and channel 9 or 19 appear alternately on the
display. The
«EMG»
icon is also displayed at the same time as channel
9 or 19. The selected channel can be modified during the dual watch.
The function can also be disabled by pushing the
PTT
(
11
) switch, the
EMG
(
6) key
or
running the
SCAN
function.
M3
(see §
MEM
on page 30)
English
Summary of Contents for JOHNSON II VOX 12/24 V
Page 1: ...Manuel d utilisation Manual del usuario Owner s manual Instrukcja obs ugi 12 24 V...
Page 54: ......
Page 55: ......