PremiumLift AirCare Max-Pro ACMaxPP User Manual Download Page 20

 

 

 

TROUBLESHOOTING

 

 
 
 

 

FAULT

 

CHECK THAT

 

STAGE 2 CHECK

 

IF PROBLEM PERSISTS

 

Some of the cells

 

appear to be deflated.

 

This is normal for alternating pressure therapy.

 

 

The mattress is made up of individual air cells. The alternating section is split up into 2 sections consisting of odd 
cells e.g. 1,3,5 etc and even cells e.g. 2,4,6 etc. These two sections will alternate through a 10 minute cycle in 

which time both sets of alternating air cells will have inflated and deflated sequentially.

 

The system does 
not  appear  to  be 
alternating.

 

1. 

Check that the static

 

mode is not turned on.

 

 

2.  Carefully mark one of the

 

inflated cells with a pen.

 

 

3.  Ensure that there are no 

kinks in the pipework down 
the side of the mattress.

 

 

4.  Check the cycle time on the 

control panel. Recommended 
setting 10 minutes unless

 

a health professional has 
recommended otherwise.

 

1.  Monitor the cell for 7 minutes

 

to see if it deflates.

 

 

2.  Straighten out any kinked 

pipes.

 

Contact Harvest Healthcare technical 
support.

 

 

Before calling:

 

 

Please ensure you have the serial number 
and model of equipment.

 

 

Please record details of the results of the 
recommended tests. (Notes pages are 
provided at the back of this user manual).

 

 
 

20

 

20

 

w

w

w

.p

re

mi
u

ml
ift

.c

o

m.
a

u

 

 

Summary of Contents for AirCare Max-Pro ACMaxPP

Page 1: ...AirCare Max Pro Digital Pump User Manual...

Page 2: ...2www premiumlift com au...

Page 3: ...AFETY INSTRUCTIONS 3 2 SAFETY INFORMATION FOR THE OPERATOR 3 3 SAFETY INFORMATION FOR THE USER 3 4 SYMBOLS USED 3 5 CLEANING DISINFECTION 3 6 SERVICING MAINTENANCE 3 7 SERVICE LIFE DISPOSAL TECHNICAL...

Page 4: ...the therapy may be reduced All hoses must be free of kinks twists and must be properly connected and positioned so as not to cause any obstruction Do not position the pump in a way that prevents acce...

Page 5: ...found on page 15 Suitableforcontinuous use Do not modify the mattress cushion or pump unit in any way Do not connect to any other medical device or equipment Not for use in an oxygen enriched environ...

Page 6: ...g pressure surface designed to reduce surface pressure on the skin and therefore reduce risk of the development of pressure ulcers in susceptable patients This pump has audible and visual alarms for l...

Page 7: ...ltoftheirvocational training or briefing are entitled to deliver assemble disassemble and transport the product 2 NON COMPLIANT USE All uses deviating from the intended purpose which may also be hazar...

Page 8: ...ct each user in the safe operation of this system before it is put into service for the first time Advise the user of any hazards which may occur if not handled correctly Only persons who have been pr...

Page 9: ...ccording to EN 60601 Handle with care This way up Keep dry Recycling symbol Refers to packaging that can be recycled cardboard Fragile handle with care This product must be disposed of in a designated...

Page 10: ...cts damageorsignsofwearmustberectifiedwithoutdelay Onlyoriginal spare parts from PremiumLift may be used otherwise all guarantees or warranties will be invalidated See pages 16 17 for Routine Maintena...

Page 11: ...6 9 12 25 minutes 345 x 115 x 185mm 3 5 kg 14 lpm Manual PUMP POWER REQUIREMENTS Power Rating Voltage Fuse MedicalClassification Safety Standards 13W AC 240V 50Hz T 1AH 250V Medical Device Class 1 EN...

Page 12: ...Pipes from the mattress connect here The pump must be able to be disconnected in an emergency for CPR to be administered B Power Switch The power switch is on the left hand side of the pump When press...

Page 13: ...ansfers Press the Cycle Time button until all 4 LED will illuminate green for Static Mode H Maxi Inflate Mode Press the Maxi Inflate button to automatically inflate the mattress to its maximum pressur...

Page 14: ...ug from the mains supply TRANSPORT MODE If the pump needs to be disconnected for any reason attach the transport cap to the feed tubes connector This will prevent deflation retaining the remaining air...

Page 15: ...s mattressesshouldbethoroughlyrinsedwithcleanwatertoremoveany residues This will help prevent any long term compatibility issues associated with disinfectant residues Alternatively disinfectionmay bea...

Page 16: ...ed clean with a mild antiseptic solution All cells are replaceable and can besourced from PremiumLift POWER UNIT Disconnect the power unit from the electricity supply before carrying out maintenance r...

Page 17: ...are Max Pro pump should be serviced every 12 months by PremiumLift approved personnel using genuine PremiumLift spare parts Failure to follow the service schedule may invalidate future warranty claims...

Page 18: ...e mains plug is not blown 4 The wall socket that the pump is connected to is working correctly 1 Connect the pump to the nearest working mainsoutlet 2 Replace the plug fuse with the correct fuse 3 Try...

Page 19: ...is not trapped in the bed mechanism Contact PremiumLift technical support Before calling Pleaseensureyouhavetheserial number and model of equipment 2 The CPR valve is not trapped and is in the closed...

Page 20: ...not appear to be alternating 1 Check that the static mode is not turned on 2 Carefully mark one ofthe inflated cells with a pen 3 Ensure that there are no kinks in the pipeworkdown the side of the ma...

Page 21: ...chnical support Before calling Please ensureyouhavetheserial number and model of equipment Please record details of the results of the recommended tests Notes pages are provided at the back of this us...

Page 22: ...PARTS LIST...

Page 23: ...e user damage D That PremiumLift s cleaning disinfecting guidelines have beenfollowed E PremiumLift smaintenance guidelines havebeenfollowed please refertothe product manual F ThatALL maintenance hasb...

Page 24: ...24 www premiumlift com au NOTES...

Page 25: ...25 NOTES...

Page 26: ...26 www premiumlift com au NOTES...

Page 27: ...au All parts and data continually undergo further development and may therefore deviate from the details given Copyright PremiumLift Our Full Terms Conditions are available by request or can be found...

Reviews: