Section 4 The Disassembly And The Relating Attention Issues To
The Part Of Product
Attention: Turn off the air-conditioner and pull out the plug of the power supply before
the service.
Part 1 Indoor unit:
No. Part
Operation
Process
Remark
1
Panel
1) Turn off the air-conditioner and cut
off the power supply;
2) Tear the adhesive tape sticking to
the panel.
3) Hold the handles at both sides of
the panel and push upward to have
it slip out;
4) Grasp the both sides of the panel
and push upward;
5) Turn the upper board by 90°and
unload it from the connecting pole
carefully;
6) Take out the filter from the right and
left side.
7) Screw off the bolts on the electrical
box cover and unload the box cover;
8) Screw off the 5 bolts (for 1Hp AC)
or 8 bolts (for 1.5Hp AC) on the
medium frame;
9) Hold the both sides of the medium
frame and open it gently;
10) Turn up the medium frame by about
90°;
11) Offload the medium frame once
hearing the crack sound;